Turbo-Cool 6” Recirculating Evaporative Cooling System Manual
16
The Sump Base must sit squarely on the floor or support surface.
3. Install the 3/4” x 4-3/4” PVC Pipe in the fitting inside the Sump Base. This
pipe serves as the overflow pipe.
Figure 11. Sump Base Installation
Sump Components Installation
Assemble the Sump Components as shown in
Figure 12
, beginning at the Pump.
The lengths of 1-1/2” PVC Pipe (Item #6) will vary depending on desired Valve
height, pad height, etc.
Note:
The 1-1/2” PVC Tee slips
inside
the bell of the Distribution Pipe.
Use teflon tape (not supplied) on threads as required. Use PVC glue on slip
connections.
Plug the electrical cord into the receptacle (not supplied).
Note: Make sure the vent hose inside the electrical cord is not obstructed.
Route the 1/4” Black Bleed Off Hose to a drain for waste water. Do not run the
bleed off hose back into the sump or trough.
Item
Description
1
3/4” Overflow Pipe
2
Trough
3
Adjustable Clamp
4
Sump Base
5
Sump Support (not supplied)