8
9
Heating element not hot
Heating element burned out
Replace the heating
element
The maximum temperature
thermostat (located under the
distributor) is set too low
Regolarlo alla temperatura
opportuna
Thermal fuse burned out
Adjust it to a suitable
temperature
Thermal fuse burned out
Thermal fuse defective
Replace with a good one
Maximum temperature
thermostat doesn't intervene
Replace
maximum
temperature thermostat
I'm not getting a suffi-
ciently dense product
The temperature of the
service thermostat (located on
the side of the distributor) is
set too low
Adjust it to a suitable
temperature
The maximum temperature
thermostat (located under the
distributor) is set too low
Adjust it to a suitable
temperature
Product excessively diluted
Increase the concentration
of the product
I'm not getting a suffi-
ciently hot product
The temperature of the
service thermostat (located on
the side of the distributor) is
set too low
Adjust it to a suitable
temperature
The bottom of the tub is not
touching the heating element
Position the tub on the
heating element correctly
PROBLEM
CAUSE
SOLUTION