Note:
Sulfuric acid and dry acid (sodium bisulfate) are not recommended for pH
adjustment. Under some conditions the electrolytic cell can be damaged.
WARNING
Read all cautions and directions provided with the muriatic acid used. Always add acid
to water. Use only with adequate ventilation. If strong odor is noticed, STOP, ventilation
is inadequate. Leave area immediately. If the work area is not well ventilated you MUST
use a properly fitted and maintained NIOSH approved respirator for acid fumes.
Fill the acid wash tank with a 5 to 1 water / muriatic acid solution.
Press NEXT to continue.
All valves on the NEXGEN are clearly marked with valve tags. The valves to be adjusted
in each step will be flashing on the screen.
STEP 1
– Close the Tank Fill Valve marked 3. Close the Product Flow Adjustment Valve
marked 4. This will allow the tank to drain for cleaning.
Press NEXT to continue.
Valve 4
Product Flow
Adjustment
Valve
Valve 3
Tank Fill
Valve