SM Install Manual
Page 21 of 35
05/05/2016
Ensure that the cord labeled ORP or Controller is plugged either into a controller or directly into
a wall outlet.
Be sure the disconnect box is in the on position.
Confirm that the output control knob located on the left side of the power supply is turned fully
clockwise.
Depending on the model, the system will begin producing chlorine in 10 to 60 seconds.
If the ChlorKing® system is linked to a chemical feed controller, adjust the output to the system
maximum, which will allow for full production every time the controller calls for it. If the system
is being operated manually, adjust the system to find the point at which chlorine levels are
maintained to the desired level. This may take several days of monitoring.
ChlorKing® systems connected to a chemical feed controller will only operate when the
controller is in feed mode. Make sure that the chemical feed controller is not set in proportional
mode or system damage may occur.
3.3 SYSTEM OPERATION
ChlorKing®
systems operate when both the main power supply and blue control cord have
power applied to them. The ChlorKing® system will continue to operate for as long as power
is applied from those two sources.
The system has an output range of 5-100% of the rated chlorine production for the model
installed and can be adjusted by turning the black knob on the side of power supply box in a
clockwise or anti-clockwise direction.
3.4 DISPLAY INFORMATION
During normal operation the display will have the following information available: