2.7 POWER SUPPLY INSTALLATION
WARNING
THE MOUNTING LOCATION OF THE UNIT MUST BE AT LEAST 1.5 METERS FROM THE
POOL.
NEVER TRY TO SUPPORT THE WEIGHT OF THE POWER SUPPLY OR ELECTROLYTIC
CELL USING ONLY DRYWALL ANCHORS.
Locate a space on the wall, in the equipment room, that will accommodate the dimensions of
the system. Mount the power supply to the wall using appropriate hardware. The power
supply must be installed no more than 8 feet from the cell housing to ensure that the cables
will reach the cell.
2.8 ELECTROLYTIC CELL INSTALLATION
WARNING
THE MOUNTING LOCATION OF THE ELECTROLYTIC CELL MUST BE AT LEAST 1.5
METERS FROM THE POOL.
Install the cell mounting bracket to the wall using appropriate hardware. Ensure that the wall
mount is level. Mount the electrolytic cell and tube to the mounting backboard. Ensure that
the cell and tube are mounted within 8 feet of the power supply and that nothing is installed
above the cell tube. The cell may need to be removed for service.