Engineering Manual Version 1.4 Page 19 of 40
This indicates that the test poll call has reached the IRIS Secure Apps system but the
security keys do not match.
If the installer has recently replace or defaulted the IRIS Touch dialler then the IRIS Secure Apps operator will
need to re-load the security key into the IRIS Touch dialler using the Allocator App.
After checking each of the configuration options the IRIS Touch dialler will then reattempt to test the connection.
Pin Alarms
Now you have the option to use pin alarms which are the IRIS Touch pin inputs which can
be used for SMS messaging or alarm signalling.
Select ‘Yes’ if you want to use the pin alarms or ‘no’ to continue.
Pin Format
You will now be asked to select which pin alarm format you wish to use.
Note: SMS only available on the IRIS Touch 600NG & 640NG diallers.
Select the format you wish to use and press ‘Continue’.
You will be presented with a warning that all current pin input settings will be lost, click
“Continue” and then click “Continue” again.
For more information on each format and additional configurations for the Pin alarms please go to the
Section 8.2
“Settings – Pin Inputs”
.
Pins Required
You will now be asked to select the pins you wish to enable and use if you have selected
SIA, FF or CID for the alarm format.
The number of pins available will depend if one of the expansion boards has been fitted.
Unselect pins you wish to disable from sending alarms and leave ticked only the pins you
want to use for alarm transmission, and then click ‘Continue’.
Monitor for tampers
You will now be asked if you want to monitor for tamper on the pin alarm inputs, which
is done using the sense resistors as detailed in
Section 7.5 “Pin Inputs”
.
Select ‘Yes’ or ‘No’ depending if you want to use this function.
Setup Complete
The Initial setup is now complete. Click ‘Finish
’
to exit the Installation Wizard and return
back to the main menu.
For advanced settings select the ‘Settings’ menu.
Once you have completed the Installation Wizard and setup any additional panel interface configuration via the
settings menu you will need to check / configure the panel for the connection method being used if not already
configured.