4. EXHAUST REQUIREMENT
4.1 EXHAUST CONNECTION
• The exhaust pipeline installation must be carried out by an authorized local technician (mandatory).
• Exhaust tubes and pipes are not supplied with the machine and must be organized by the customer.
• Connect the exhaust pipeline to the outside. Thermo-insulation of the exhaust pipes is
recommended.
• The maximum length of the pipeline is 1 0 meters. For longer piping it is necessary to increase the
diameter of the pipe or install a suitable aspirator.
• Limit the number of curves and horizontal sections. Curved tubes must have a max. angle of 45 °.
• The exhaust extractor fan for the dryer is built inside the machine.
• An oily liquid will form in the ducting from the condensation of the vapors. It is necessary to seal all
joints with special oil-resistant silicone, and ensure that the path of the pipes does not overhang an
area where falling drops can cause damage.
PARAMETER
VALUE
1 80 m
3
/h
1 50 mm
(max 1 0 meters with 2 curves; for longer lengths
or twisty pipeline, increase the diameter)
Top of the machine.
Flange is delivered with the machine
Galvanized Iron
Exhaust flow rate
Connection diameter
Location of the connection
Material type