background image

Page 2

IMPORTANT

MODEL SSI-22 GAS INSERT

Not for Use with Solid Fuel

Units Available

•  

  - Natural Gas & Propane

Thermostatically Controlled Blower Included

Pilot Generator - 

No Electric Current Required

    

For Remote Switch Burner Operation

Rating and Instruction Plate in Control Cavity

Electricity Required for Fan Operation

BLOWER CONTROL

GAS CONTROL VALVE

WITH IGNITOR

MAIN BURNER ON/OFF

SAVE THESE INSTRUCTIONS

FOR YOUR SAFETY

THIS APPLIANCE REQUIRES AIR FOR PROPER COMBUS-
TION.  ALWAYS PROVIDE ADEQUATE COMBUSTION AND
VENTILATION AIR. FOLLOW INSTRUCTIONS AND INFOR-
MATION IN THE LATEST EDITION OF THE

 

NATIONAL

FUEL GAS CODE ANSI Z223.1 (USA), OR CSA B149
- GAS INSTALLATION CODE (CANADA)

REGARDING REQUIREMENTS FOR COMBUSTION AND
VENTILATION AIR.

This fireplace must be installed in accordance with these instructions. Read carefully ALL the instructions in
this manual first. Consult the building authority having jurisdiction to determine the need for a permit prior to
beginning the installation.

NOTE: 

An improperly installed, adjusted or maintained appliance may void your fire insurance.

INSTALLATION DATA

Model SSI-22 Gas Insert comes assembled with glass front.
Remove all packaging materials around glass before op-
eration of appliance. Install logs and coals as shown on
page 9 before operation.

An optional heat circulating fan is factory installed on this
unit. The fan is thermostatically controlled to turn on and
off automatically for optimum performance. A three-wire
grounded extension cord with plug is included and should
be connected to a properly grounded receptical.

No electrical supply is required for the gas system
operation. The self generating pilot provides current for
the Burner On/Off Switch. 

Do not wire to 110 volt AC

outlet!

SPECIAL OPERATING INSTRUCTIONS

Due to high temperatures, the appliance should be

  located out of traffic and away from furniture and
  draperies.
- Advise all adults and especially children to be alert  to the
  hazard of high surface temperatures and that  they should
  stay away to avoid burns or clothing ignition.
- Supervise young children when they are in the  same room
  as the appliance.
- Never place clothing or flammable material on or near the
  appliance.
- It is important that the control compartments, burners and
  circulating air passageways of the appliance be kept clean.
- Installation and repair should be done by a qualified
  service person (licensed gas fitter). The appliance  should
  be inspected before use and at least annually by a qualified
  service person. More frequent cleaning may be required
  due to excessive lint from carpeting, bedding material, etc.
- Do not use this appliance if any part has been under
  water. Immediately call a qualified service technician to
  inspect the appliance and to replace any part of the control
  system which as been under water.

NOTE: 

This unit must be installed in accordance with the

latest edition of the National Fuel Gas Code ANSI Z223.1
(USA) or CSA B-149 (Canada) and any local codes.

The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the absence
of local codes, with the latest edition of the National Electri-
cal Code, ANSI/NFPA 70, or CSA-C22.2 (CANADA)

Summary of Contents for SSI-22

Page 1: ...nce Openwindows extinquishallflames Do not touch any electrical switch do not use anyphone in your building Immediately call your gas supplier from a neighbour s phone Followthegassupplier sinstructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This product may be installed i...

Page 2: ...extension cord with plug is included and should be connected to a properly grounded receptical No electrical supply is required for the gas system operation The self generating pilot provides current for the Burner On Off Switch Do not wire to 110 volt AC outlet SPECIAL OPERATING INSTRUCTIONS Due to high temperatures the appliance should be located out of traffic and away from furniture and draper...

Page 3: ...appliance Two front finishing surrounds are available to accommodate a wide range of fireplace openings as listed below A Small Trim B Large Trim Minimum Depth Minimum Width Maximum Width Minimum Height Maximum Height Minimum Mantle Height Maximum Mantle Depth For small openings which allow little access the flue collar assembly can be removed and connected to the vent system liner before the appl...

Page 4: ...put Minimum 4 5 wc 11 wc Input Maximum 10 5 wc 13 wc Manifold Pressure 3 5 wc 10 wc ELECTRICAL FAN 120V 60HZ Less than 5 AMPS GAS CONNECTION Provide a 1 8 inch N P T plugged tapping accessible for test gauge connection immediately upstream of the gas supply connection to the appliance WARNING The Rating Plate indicates the type of gas to be used in your unit Do not use a different gas For units eq...

Page 5: ...ed and a proper draft is present when the unit is in operation See Checking Proper VentAction Page 7 VENTING ATTACH B VENT TO COLLAR USING 3 SHEET METAL SCREWS B VENT OR CHIMNEY LINER FLUE COLLAR 10 FT OR GREATER 2 FT MIN LESS THAN 10 FT 2 FT MIN 3 FT MIN a Remove the flue collar assembly from the appliance by removing the mounting screw in the top front flange lifting flue collar up and pull forw...

Page 6: ...tions or failure to use parts specifically approved with this appliance may result in property damage or personal injury 1 The installer must attach the markings supplied with the gas insert to the fireplace into which the factory built insert is installed The marking must be mechani cally installed to the side of the firebox 2 No cutting of any sheet metal parts of the factory built fireplace whi...

Page 7: ...on monoxide co poisoning and possibly death CHECKING PROPER VENT ACTION Periodically check for proper vent action and at least annually inspect venting system for any blockage 1 Operate appliance for at least 15 minutes with heat circulating fan off 2 Using a match or cigarette check to see that air is being drawn into draft hood located behind the top air outlet grill see illustration below VERIF...

Page 8: ... not to scratch parts NOTE Side parts are interchangeable from left to right 3 Install nuts and bolts as shown in figure below Note If you have purchased the optional brass face kit refer to instructions in that kit before installing side brass trim 4 Install side brass trims over the outer edges of face as shown Attach with brass screws provided Make sure trim with switch knock out is located on ...

Page 9: ...wing coals or ashes Do not use any materials other thatn approved parts by Chinook Fireplace 1 Remove all packaging materials from logs and from inside the combustion chamber 2 Place the ember support mesh on top of the rear burner 3 Place the log bracket onto the burner carryover 4 Place the rear log in the back of the combustion chamber It should rest against the stops behind the rear burner and...

Page 10: ... 1 Turn off gas and electricity to fireplace insert 2 Remove the glass front 3 Remove the logs and burner assembly Disconnect the wires from the temperature switch as you remove the burner 4 Remove the two 2 fan mounting nuts 5 Disconnect the wires from the fan and remove blower 6 Re install all parts in reverse order as removed If any of the original wire as supplied with the appliance must be re...

Page 11: ...losion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water E Keep burner and control compartment clean See installation and operating instructions accompanying appliance F This appliance must be installed in accordance with l...

Page 12: ...ugh to engulf the generator bulb on one leg and reaches toward the Burner Tube on the other leg The pilot should be burning smooth 3 Check to see that the both burners ignite instanta neously on all openings when turned on When this is checked out and cleaned replace the logs See installa tion instructions on Page 9 4 Have vent system inspected periodically by a qualified agency to insure that it ...

Page 13: ...itch NOTE A remote control or thermostat can be connected in conjunction with the on off switch Connect each as show below Do not exceed recommended wire length in table below INITIAL BURNING PLEASE NOTE It is normal for your unit to give off some odor the first time it is burned This is due to the curing of the paint and any undetected oil from the manufacturing process Please ensure that your ro...

Page 14: ...essure readings Inlet pressure can be checked by turning screw A counterclockwise 2 or 3 turns and then placing pressure gauge tubing over the point Gauge should read 7 minimum 4 5 water column for natural gas or 13 11 minimum water column for propane Outlet pressure can be checked the same as above using screw B Gauge should read 3 5 water column for natural gas or 10 water column for propane AFT...

Page 15: ...ithinahorizontalradiusof10ft ofthechim ney Turnonpilotflame Increasepilotflameby turningpilotadjustmentscrewcounter clock wise Clean thermopile and thermopile connection to valve Reconnectthermopiletovalve finger tight thentightenonequarterturnwitha wrench Shortenwiretocorrectlengthorwiregauge Replace Loosen and tighten thermocouple Clean thermocouple and valve connection Replace thermocouple Repl...

Page 16: ...ront Primary Air LP Grille Top Grille Bottom Glass Blower Recirculation Ember Package Blower Control Knob Blower Switch sensor Glass Gasket Power Cord Push Igniter Vent Safety Switch Burner U Clip ACCESSORIES MODEL SSI 22 GAS INSERT 4745139 Refractory Brick 4745136 Small Trim Kit PB 4745137 Large Trim Kit PB 4745138 3620 Trim Kit Blk PB 4745141 640 ZC40 Trim Kit Blk PB 4745140 Bay Window 4745135 C...

Page 17: ...ENTIONAL FIREPLACE FUELS BURNING OF WOOD COAL OR OTHER SOLID FUEL WILL CAUSE DAMAGE TO OUR PRODUCTS PRODUCE EXCES SIVE TEMPERATURES AND RESULT IN A FIRE HAZARD If you believe that a product fails to meet the above limited warranty you should notify us in writing prior to expiration of the applicable warranty period set forth above at the following address Viking Gas Technologies Calgary Alberta T2...

Page 18: ..._______ Installation Date ________________________ Serial _________________________________ Dealer Name __________________________ INSTALLATION INFORMATION Keep in a safe place for future reference MODEL NUMBER _______________________________ SERIAL NUMBER _______________________________ INSTALLATION DATE ____________________________ DEALER NAME _________________________________________________ Ad...

Page 19: ...Page 19 NOTES ...

Reviews: