15
This alarm is used to asking for help to all authorized users. It is always enabled, and will be triggered
when:
—
the user presses the SOS button for 3 seconds, or
When the alarm is triggered, it will be sent at a interval of 3 minutes, and can be stopped when:
—
the device receives command “nohelp”, or
The device receives command “mask”
4.
Shock Sensor alarm
Alarm indication: “shake alarm!!!”
This alarm is enabled when:
—
the device receives command “arm”, if the device didn’t receive command “shake” before,
and set the trigger level to 2, or
—
the device receives command “shake” with a level higher than 0, and set the trigger level to
the value specified in the command.
This alarm is disabled when:
—
the device receives command “noarm”, if this alarm is not enabled by command “shake”, or
the device receives command “shake” with a level of 0..
When the alarm is enabled, it will be triggered when:
—
the shock sensor detects a shaking with a level higher than the trigger level.
When the alarm is triggered, it will be sent at an interval of 3 minutes, and can be stopped when:
—
the device receives a command of “mask”.
5.
Move alarm
Alarm indication: “move alarm!!”
This alarm is enabled when:
—
the device receives command “arm”, or
—
the device receives command “move”.
This alarm is disabled when:
—
the device receives command “noarm”, or
—
the device receives command “nomove”
When the alarm is enabled, it will be triggered when:
—
the device detects the devices leaves the place at where the alarm is enabled..
When the alarm is triggered, it will be sent at an interval of 3 minutes, and can be stopped when:
—
the device receives a command of “mask”, or
—
the device detects the vehicle is back to the original place.
Attention:
—
If both acc alarm and move alarm are triggered, the device will only send move alarm.
Attention:
This alarm can neither be enabled nor triggered unless the GPS works well (receiving signals from more than
3 GPS satellites)
6.
Geo-fence alarm
Alarm indication: “move alarm!!”
This alarm is enabled when:
—
the device receives command “stock”.
This alarm is disabled when:
—
the device receives command “nostock”.
When the alarm is enabled, it will be triggered when:
—
the device detects the devices is out of the geo-fence.
When the alarm is triggered, it will be sent at an interval of 3 minutes, and can be stopped when: