Page 20 of 60
MULTI-FUEL
Nominal Output
Total Energy Efficiency %
CO content @13% O
2
Dust Concentration @ 13% O
2
NOx mg/m
3
Cx Hy mg/m
3
Flue Gas g/s
Mean Flue gas temp. °C
Smoke Control/DEFRA Exemption Testing complete
Suitable For Smoke Control Zones (Factory Fitted)
Max. Log length x average diameter
Max. Fuel load
Flue Collar Diameter
Flue Size Required
Top Exit
Rear Exit
Hearth Type No Base Heat Shield/Plinth
Hearth With Base Heat Shield/Plinth
Chimney draught required
Construction
Weight
Tested to EN13240:2001-2004 / BS 3841-2:1994
For distances to combustibles / non-combustibles see section 3
WOOD
4.8kW
83%
0.09%
20mg/m
3
106mg/m
3
89mg/m
3
3.9g/s
231°C
Yes
Yes
400mm x 100mm
2.5kg
127mm
Min 125mm
Standard
RHA/RVA Required
Constructional
12mm
12Pa
Welded steel
97kg
SMOKELESS FUEL
5kW
87%
0.04%
16mg/m
3
161mg/m
3
11mg/m
3
2.9g/s
223°C
Yes
Yes
3kg
127mm
Min 125mm
Standard
RHA/RVA Required
Constructional
12mm
12Pa
Welded steel
97kg
The
Tech Details
(Woody Eco (Aml Danwydd))
Spares are available through your local Chilli stockist or
our online shop. There are diagrams online to help you
identify the correct parts and advice about how to fit:
www.chillipenguin.co.uk/FAQ/looking-after-your-penguin