Page 12 of 60
MULTI-FUEL
Nominal Output
Total Energy Efficiency %
CO content @13% O
2
Dust Concentration @ 13% O
2
NOx mg/m
3
Cx Hy mg/m
3
Flue Gas g/s
Mean Flue gas temp. °C
Smoke Control/DEFRA Exemption Testing complete
Suitable For Smoke Control Zones (Factory Fitted)
Max. Log length x average diameter
Max. Fuel load
Flue Collar Diameter
Flue Size Required
Top Exit
Rear Exit
Hearth Type No Base Heat Shield/Plinth
Hearth With Base Heat Shield/Plinth
Chimney draught required
Construction
Weight
Tested to EN13240:2001-2004 / BS 3841-2:1994
For distances to combustibles / non-combustibles see section 3
WOOD
4.7kW
81.2%
0.10%
33mg/m
3
135mg/m
3
96mg/m
3
4.8g/s
224°C
Yes
Yes
270mm x 100mm
2.5kg
127mm
Min 125mm
Standard
Fit flue collar to rear
Constructional
12mm
12Pa
Welded steel
104kg
SMOKELESS FUEL
4.8kW
87%
0.06%
12mg/m
3
119mg/m
3
37mg/m
3
2.9g/s
247°C
Yes
Yes
3kg
127mm
Min 125mm
Standard
Fit flue collar to rear
Constructional
12mm
12Pa
Welded steel
104kg
The
Tech Details
Spares are available through your local Chilli stockist or
our online shop. There are diagrams online to help you
identify the correct parts and advice about how to fit:
www.chillipenguin.co.uk/FAQ/looking-after-your-penguin