1.  WARNING - FOR YOUR SAFETY - READ THE FOLLOWING SAFETY PRECAUTIONS BEFORE OPERATING THE WATER CHILLER

 

 

 

To prevent electric shock, unplug the Chiller prior to servicing.  Never remove the cover while the Chiller is still 

connected to electricity.   

 

Never insert anything into the Chiller cabinet when it is connected to electricity.  Prevent water from flowing into 

the Chiller metal cabinet or onto electrical parts. 

 

Do not use with water that is microbiologically unsafe or of unknown quality. 

 

When carrying or tilting the Chiller never tilt more than 45 degrees in any direction.  Always allow the Chiller to 

stand fully upright for 4 hours before connecting to electricity to allow the compressor’s lubricant to settle.  

Failure 

to do so may cause compressor failure.

 

 

In case of failure, cut off the power and water supply immediately, and contact an authorized service center or 

Chiller Daddy at 

[email protected]

 

WARNING: GROUNDING SAFETY PRECAUTIONS AND INSTRUCTIONS - The Chiller must be grounded – if the 

appliance is improperly grounded, the result could be electric shock. To provide additional protection from the risk 

of shock, the Chiller MUST be connected to a ground fault circuit interrupter (GFCI) outlet at all times.   Do not use 

an extension cord or 3 prong adaptor.   Ensure that the Chiller is set up so access to the power outlet and plug is 

unobstructed.  If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly 

qualified persons in order to avoid a hazard. 

 

IMPORTANT: The customer acknowledges that water, like other liquids, can cause damage to surfaces. The 

customer takes full responsibility for placing the Chiller within a residence or business and acknowledges that 

failure to address drips, leaks or spillages is at the customer’s risk. 

 

The Chiller is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or 

lack of experience and knowledge, unless they have been given supervision or instruction.  Children being 

supervised are not to play with the Chiller.   

 

Be certain to check the drain plug on the bottom of the Chiller to insure that it is tight and does not leak.  Shipping 

and handling may have caused the drain plug to loosen. 

 

2.  LOCATION REQUIREMENTS 

 

 

                                                                                                                                                                                            

 

 

This Chiller is intended to be installed underneath a conventional kitchen sink, in a cabinet not less than 36” 

(914mm) wide (inside dimension). Chiller Daddy® may be installed in any location in the cabinet base as long as 

there is a minimum of 5” (127mm) between the Chiller and the cabinet walls.  In order to have necessary air 

exchange for the Chiller, a free air opening of at least 60 square inches (387 cm²) should be provided in the kitchen 

cabinet to allow heat to escape.  The opening should be located as close to the Chiller as possible.  

 

Make sure the cabinet floor is flat and even where the Chiller is to be installed.  An unbalanced installation may 

cause noise and vibration of the Chiller.  All 4 vibration absorbing feet should be in firm contact with the cabinet floor.  

Be sure the cabinet floor is strong enough to support the Chiller when filled with water.   

 

Do not install the Chiller where the temperature will go below 50° F (10° C) or above 100° F (38° C). 

 

Ensure that the supply water pressure rating is suitable for use with the application (15~100 PSI (100~690kPa). 

 

Check the available power supply against the Chiller data plate to assure correct electrical service. 

 

Chiller Daddy is for indoor use only.  Keep away from direct sunlight and excessive humidity.   Avoid harmful gas, 

chemicals, moisture or excessive heat.  Do not store explosive substances such as aerosol cans with a flammable 

propellant with the Chiller. 

 

3.  INSTALLATION  PROCEDURES 

 

 

 

Do not plug Chiller in to the electrical outlet before connecting the Chiller to the water supply.  If you need to 

unplug the Chiller wait at least 5 minutes before plugging in again.   

 

Remove the Connector Plugs from the Quick Connector Union on the stainless steel water inlet and outlet tubes on 

the top of the Chiller. See Section 7, Step 4 for instructions on Tube and Plug removal from Quick Connector Union 

fittings.  Save for possible future use.    

 

Connect the 1/4” OD tube from the outlet line of the Reverse Osmosis or Water Filtration system to the water inlet 

of the Chiller by using the Quick Connector Unions. (see Section 7)   The tubing must be acceptable for use with 

potable water.  Flush water through the lines of the Chiller and drinking water system for one minute before 

installing the faucet.  Use 1/4” OD tubing to connect the water outlet of the Chiller to the faucet.  Adaptors to 

Summary of Contents for CHL-501

Page 1: ...Y COMPONENTS DIAGRAM 9 ADJUSTING THERMOSTAT 10 SPECIFICATIONS 11 TROUBLESHOOTING GUIDE 12 WARRANTY SERVICE ChillerDaddyLLC Huntington IN 46750USA www ChillerDaddy com For best use of your Chiller we a...

Page 2: ...caused the drain plug to loosen 2 LOCATION REQUIREMENTS This Chiller is intended to be installed underneath a conventional kitchen sink in a cabinet not less than 36 914mm wide inside dimension Chille...

Page 3: ...l use 30 insulated OD faucet connection poly tube is included This insulated tube not only helps to keep the water colder but also prevents condensation from forming on the tube and running down onto...

Page 4: ...ke sure to start with a clean tube without any foreign material free of score marks and scratches Use a utility knife with a fresh blade or Tube Cutter Do NOT use a hacksaw Step 2 Inserting the Tube W...

Page 5: ...ng 8 PRIMARYCOMPONENTSDIAGRAM 9 ADJUSTINGTHERMOSTAT The thermostat is factory preset and requires no adjustment other than for abnormal requirements If needed the water temperature can be adjusted by...

Page 6: ...Power 110 Volts 60Hz 3 Prong Grounded Cord Attached 1 8A 140W Motor Compressor Thermally Protected Certifications Conforms to UL Standard 399 Certified to CSA Standard C22 2 s 60335 2 24 60335 1 Refri...

Page 7: ...the thermostat as necessary The ambient temperature is high It is normal for the Chiller to run continuously at high ambient temperatures C Water is not cold but the Chiller compressor runs continuous...

Page 8: ...erial number Please retain your receipt or invoice as proof of purchase date and location This warranty applies only in the country in which the unit was originally sold This Limited Warranty does not...

Reviews: