2
1. WARNING - FOR YOUR SAFETY - READ THE FOLLOWING SAFETY PRECAUTIONS BEFORE OPERATING THE WATER CHILLER
To prevent electric shock, unplug the Chiller prior to servicing. Never remove the cover while the Chiller is still
connected to electricity.
Never insert anything into the Chiller cabinet when it is connected to electricity. Prevent water from flowing into
the Chiller metal cabinet or onto electrical parts.
Do not use with water that is microbiologically unsafe or of unknown quality.
When carrying or tilting the Chiller never tilt more than 45 degrees in any direction. Always allow the Chiller to
stand fully upright for 4 hours before connecting to electricity to allow the compressor’s lubricant to settle.
Failure
to do so may cause compressor failure.
In case of failure, cut off the power and water supply immediately, and contact an authorized service center or
Chiller Daddy at
.
WARNING: GROUNDING SAFETY PRECAUTIONS AND INSTRUCTIONS - The Chiller must be grounded – if the
appliance is improperly grounded, the result could be electric shock. To provide additional protection from the risk
of shock, the Chiller MUST be connected to a ground fault circuit interrupter (GFCI) outlet at all times. Do not use
an extension cord or 3 prong adaptor. Ensure that the Chiller is set up so access to the power outlet and plug is
unobstructed. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
IMPORTANT: The customer acknowledges that water, like other liquids, can cause damage to surfaces. The
customer takes full responsibility for placing the Chiller within a residence or business and acknowledges that
failure to address drips, leaks or spillages is at the customer’s risk.
The Chiller is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction. Children being
supervised are not to play with the Chiller.
Be certain to check the drain plug on the bottom of the Chiller to insure that it is tight and does not leak. Shipping
and handling may have caused the drain plug to loosen.
2. LOCATION REQUIREMENTS
This Chiller is intended to be installed underneath a conventional kitchen sink, in a cabinet not less than 36”
(914mm) wide (inside dimension). Chiller Daddy® may be installed in any location in the cabinet base as long as
there is a minimum of 5” (127mm) between the Chiller and the cabinet walls. In order to have necessary air
exchange for the Chiller, a free air opening of at least 60 square inches (387 cm²) should be provided in the kitchen
cabinet to allow heat to escape. The opening should be located as close to the Chiller as possible.
Make sure the cabinet floor is flat and even where the Chiller is to be installed. An unbalanced installation may
cause noise and vibration of the Chiller. All 4 vibration absorbing feet should be in firm contact with the cabinet floor.
Be sure the cabinet floor is strong enough to support the Chiller when filled with water.
Do not install the Chiller where the temperature will go below 50° F (10° C) or above 100° F (38° C).
Ensure that the supply water pressure rating is suitable for use with the application (15~100 PSI (100~690kPa).
Check the available power supply against the Chiller data plate to assure correct electrical service.
Chiller Daddy is for indoor use only. Keep away from direct sunlight and excessive humidity. Avoid harmful gas,
chemicals, moisture or excessive heat. Do not store explosive substances such as aerosol cans with a flammable
propellant with the Chiller.
3. INSTALLATION PROCEDURES
Do not plug Chiller in to the electrical outlet before connecting the Chiller to the water supply. If you need to
unplug the Chiller wait at least 5 minutes before plugging in again.
Remove the Connector Plugs from the Quick Connector Union on the stainless steel water inlet and outlet tubes on
the top of the Chiller. See Section 7, Step 4 for instructions on Tube and Plug removal from Quick Connector Union
fittings. Save for possible future use.
Connect the 1/4” OD tube from the outlet line of the Reverse Osmosis or Water Filtration system to the water inlet
of the Chiller by using the Quick Connector Unions. (see Section 7) The tubing must be acceptable for use with
potable water. Flush water through the lines of the Chiller and drinking water system for one minute before
installing the faucet. Use 1/4” OD tubing to connect the water outlet of the Chiller to the faucet. Adaptors to