Electrolux air-o-chill

Blast Chiller/Freezers 30-25kg

Chilling means bringing the temperature of cooked food from +90ºC to +3°C in a short time lap which does not allow 
bacterial growth .Electrolux Blast Chillers/Freezers reduce temperature from +90ºC to +3°C at food core in less than 90 
minutes and down to -18ºC in less than four hours: the model detailed on this sheet performs this cycle up to a 30 kg full 
load. After the Blast Chilling/freezing process a holding cycle starts automatically to respectively maintain food at +3 and 
-18 °C. Blast freezed food has a solid 6 months/1 year shelf life without loss of flavour, nutritional values and weight. The 
opportunity to prepare in a single shot the food to be used in different times during the week enables a better work 
scheduling and therefore a sensible reduction in labour costs.

726346

 
OPERATING MODES

 Cruise: the chiller automatically sets 

the parameters for the quickes and 
best chilling (it works by probe).

 Soft Chilling (Air temperature –2°C).

 Hard Chilling (Air temperature 

–20°C).

 Shock freezing (Low air temperature 

adjustable up to -41 ºC.)

 Holding at +3°C or -18ºC 

(automatically activited at the end of 
each cycle).

 All the probe-driven cycles feature 

ARTE (Algorithm for Remaining Time 
Estimation) to make planning the 
activities easier.

 Holding at +3°C (automatically 

activated at the end of each cycle).

 Turbo cooling: the chiller works 

continuously at the desired 
temperature. Ideal for continuous 
production.

 It is possible to operate by time or 

by probe.

 The control unit provides several 

operating settings: time/core 
temperature according to NF and UK 
regulations, time/air 
temperature/probe personalised 
according to national regulations, 
sterilizing cycle: UV lamps built-in (on 
request), 3 single sensor core 
temperature probes (as accessory), 
ideal for meats, automatic defrosting 
and manual defrosting. All parameters 
are programmable.

 3-sensor core probe as standard 

and automatic detection of the core 
probe insertion.

 The control unit provides two large 

displays to read out: time, core 
temperature, cycle countdown, 
alarms, service information. 

 Suitable for ambient temperatures 

up to 32°C.

 Two specialized cycles, P1 brings 

down ice-cream temperature to -14°C 
(measured at the core when probe is 
inserted). Once set temperature is 
reacheed, the temporary maintenance 
phase automatically begins, holding 
the -14°C temperature. P2 sets 
temperature to -36°C / -40°C for an 
indefinite amount of time, maintaining 
the ventilation active. Temperature is 
adjustable up to -40°C without 
interrupting the cycle, allowing 
ice-cream to be kept longer in the 
freezer. 

 All information related to the 

different operating models are 
recorded: date, time, cycle, core 
temperature, holding temperature, 
HACCP accordance.

 An audible alarm starts when the 

cycle ends or terminates abnormally.
 

Reviews: