Chapter 2 Components Identification
40
2.4.3
Indications During Operation
The Up/Down arrow buttons cycle through indications.
OP **.**kPa
SP **.**kPa
DP **.**kPa
EP **.**kPa
External pressure
Suction pressure
Differential pressure
Exhaust pressure
Blower ***.*°C
Temperature around blower
Motor *****rpm
Motor rotational frequency
Indicates the rotational frequency of the currently running motor.
Runtime ******h
Accumulated run time (resettable)
Indicates run time accumulated since the last resetting.
Accumulated run time reset mode (
Total ******h
Actual run time (not resettable)
Indicates the total run time.