1.4 

運転 

Operation 

 

運転中に移動させないで下さい。

 

Do not move it during the operation. 

 

停電した時には、電源を切って下さい。復旧時に、けが・装置破損の原因になります。

 

Turn OFF the power when an instantaneous power interruption occurs. 
Otherwise, injury or product damage may be caused when the product recovers. 

 

フィルタを取り外したり、目詰まりや破損した状態で運転すると、

 

ブロア内への異物が混入して、故障の原因となります。  正しくフィルタを取り付けてご使用ください。

 

Operation  without  filter  or  with  a  clogged  and  damaged  filter  may  cause  trouble,  because  foreign 
substances enter the blower. Install the filter properly before operating the machine. 

1.5 

修理・分解・改造

   

Repair, disassembly and modification

 

 

本体を分解・改造しないで下さい。感電・けがの原因になります。内部の点検や修理はお買い上げになった販売店に
連絡して下さい。

 

Do not disassemble or modify the machine. 
Disassembly and modification may cause an electrical shock and injury. 
Contact your dealer for internal inspection and repair. 

1.6 

廃棄

   

Disposal

 

 

産業廃棄物として適切に処分してください。

 

Dispose of the product properly as industrial waste 

2

 

製品到着時の確認

  Confirmation and Preparation at Arrival 

 

開梱されましたら、各部の不足部品がないかご確認下さい。

 

万一、運送途中での破損・部品不足などがございましたら、すぐにご連絡下さい。

 

After unpacking, make sure that all parts are provided. 

Contact our company immediately if parts are damaged during transportation or not provided.

 

 

本体

  Main Body 

製品ネームプレートは本体背面に貼っていますので、ご確認下さい

 

Confirm the nameplate

back

 

side

.

 

 

 

電源ケーブル(付属)とリモートケーブル(別売) 

 

Power cable(standard accessory) and Remote cable(option) 

 

 

 

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 
 
 
 

リモートケーブル(別売)    MT-173-8 

Remote cable(option)

(3m)  ×1 

抜け防止の設計となっております。くぼみを下にし、しっかりと差し込んで
下さい。

(ピンの位置を必ず確認してください) 

The remote cable is so designed as to be prevented from falling off. 
Insert it securely with its dent facing downward. 
(Make sure to confirm pin positions.) 

電源ケーブル

Power cable

 

(3m)  ×1 

※  ケーブルは地域によって異なります。 
※  The cable is different in each region. 

 

100-115V 国内 

(Japan) 

本体差し込みプラグ 

/コンセントプラグ 

Power cord plugs 
for main unit side 

and power supply 

socket 

 

200V  国内 

(Japan) 

本体差し込みプラグ 

/コンセントプラグ無 

(切落し) 

Power cord plug 

for main unit side 

and   

without plug

 

(cut 

cable end) for 

power supply 

socket 

 

220-240V  海外

(Other than Japan) 

本体差し込みプラグ 

/コンセントプラグ 

Power cord plugs 
for main unit side 

and power supply 

socket 

 

 

Summary of Contents for CBA-1000AT2-HC-DSA-V1

Page 1: ...arker is an energy saving type clean box that realizes air technology in a compact body Please read this instruction manual thoroughly and handle this machine correctly so that you can use it safely f...

Page 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Page 3: ...AT panel 9 4 3 Remote connector 12 4 4 Confirmation before operation 13 4 5 Operation procedure 13 5 Remote Cable Sold Separately 14 5 1 Electrical circuit diagram 14 5 2 Color and signal of each wir...

Page 4: ...t outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electri...

Page 5: ...Dispose of the product properly as industrial waste 2 Confirmation and Preparation at Arrival After unpacking make sure that all parts are provided Contact our company immediately if parts are damage...

Page 6: ...Secondary filter CHF 2030 50 Active Carbon Cassette ACC 3220 100 Exhaust filter HEP 3220 69 Remove the sticker before use 1 1 1 The sticker is pasted to the filter when shipping it To prevent the zeo...

Page 7: ...econdary filter Protecting the circuit and the blower Active carbon cassette Absorbing the odor HEPA Exhaust HEPA filter Exhaust treatment 1 Primary filter Zeolite Cassette Filter Shaking motor Active...

Page 8: ...o match usage conditions the installed flange can be changed without having to use any tools Replacement flanges are sold separately 75 Removal method Turn the flange counterclockwise to remove it Tur...

Page 9: ...ilure Never adopt star burst connection that may cause voltage drop If voltage drop occurs longer time is required for startup 3 ON OFF 30 3 ON OFF It causes the trouble if ON OFF is frequently operat...

Page 10: ...to perform vibration manually after a short operating time cumulative time of less than 1 hour press the OFF button then press and hold the Manual Vibration button for 20 seconds Vibration continues...

Page 11: ...utomatically activates the vibration function Operating Pressure Indication Pa Indicates the current operating pressure level kPa 0 2 Pa 0 2 Pa When the equipment is not operating the pressure indicat...

Page 12: ...ours Indicator lamp Shaking 0 1hour After automatic shaking Off Hand operation shaking 1hour After automatic shaking Light up Automatic shaking 24 Some estimate of the number of shaking times for 24 h...

Page 13: ...icator lamp of AT panel lights AT ON Press the ON switch to start operation Confirm that abnormal sounds such as metallic sounds are not generated Confirm that the suction hose is connected securely 4...

Page 14: ...Temperature correction is not provided Reference example 3 5 6 33 0 1 F Attach a noise limiter Approximately 33 0 1 F to the output terminals Nos 1 2 and 3 When adding inductors such as relays 33 0 1...

Page 15: ...operation Red white Remote control operation switching signal Short circuits the wires 4 and 8 to start remote operation The AT panel is disabled while the wires 4 and 8 are short circuited Yellow Cha...

Page 16: ...the capacity level is changed the set level is stored in memory The set capacity level remains in memory even after the main power switch is turned off AT ON Lo Hi To change the capacity level using...

Page 17: ...ration 1 20 Auto operation shake off total up 1 hours After stopping the operation Auto moving for 20sec 20 Hand operation shake off After stopping the operation put on the manual shake off button for...

Page 18: ...disconnect the power plug from the electrical outlet before starting inspection Do not confuse the back and front of the filter The filter grid frame should be located on the exhaust side Release 2 s...

Page 19: ...sitioned at the center move the vibration arm to the end position before removing the guard or other parts 2 Remove 2 screws on both sides of the guard for shaking and get the guard off The guard for...

Page 20: ...ve carbon ACC 3220 100 ACC ACC plate 1 ACC Move up the ACC plate and remove active carbon 1 4 Release 4 snap locks and remove exhaust filter cover Exhaust filter cover 4 snap locks 2 Remove exhaust fi...

Page 21: ...it 2 Applicable fuse CBA 1000AT2 HC DSA V1 100 115V 10A 2 CBA 1000AT2 HC DSA V1 T 200V CE 220 240V 5A 2 Inspection item Frequency Description Filter case Before operation Is the case closed completely...

Page 22: ...filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status Start the operation 30 minutes later Fu...

Page 23: ...Copyright CHIKO AIRTEC CO LTD 2013 23 9 Indication of DANGER Labels 10 Electrical Circuit Diagram...

Page 24: ...y side when hose is connected to the suction port Before the zeolite adheres to the Primary filter After 2 5 2 7 m 3 min Machinery Directive EN ISO12100 1 2003 EN ISO 12100 2 2003 EN ISO14121 1 2007 E...

Page 25: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Reviews: