5.2 

各線の色と信号について

Color and signal of each wire 

 

入力 

INPUT

  :①  接点入力

(無電圧接点

Contact input (no-voltage contact) 

 

インピーダンス

    Impedance 

1.0

Ω   

 

出力 

OUTPUT

:③~⑥(④除く)オープンコレクタ 

Open collector 

 

耐圧

Voltage resistance 50

V  (≦

100 mA

 

入力電圧範囲  :⑦    電圧入力

0

5V 

Input voltage range:

⑦ 

Voltage input of 0 to 5V

 

 

インピーダンス 

10.0

kΩ  ※

+5.0V

以上印加させないでください。

 

Impedance:10.0k

Ω  ※

Do not apply voltage exceeding 

5.0V.

 

 

7

番ピンの印加電圧閾値表>

 

能力レベル

 

Capacity level 

電圧

(DCV) 

Voltage(VDC) 

0.6

1.1 

1.2

1.7 

1.8

2.3 

2.4

2.9 

3.0

3.5 

3.6

4.1 

4.2

5.0 

     

※誤差が±

4%

ある為、電圧を設定する際は、各レベルの中点の                                                                                   

 

     

   

電圧を印加してください。

         

 

           

When setting the voltage,apply a mid-point voltage value for 

                                                                         

 

                each level since the error range is 

±

4%. 

線色

 

 

Wire color

 

PIN

 

NO. 

信号名称 

  Signal

 

name 

 

役割 

  Role 

黒 

   

Black

 

 

運転入力信号 

 

Operation input signal 

遠隔信号

(

入力

Rem

o

te

 s

ig

n

a

ls

 

④⑧を短絡後、①を短絡して運転を開始します

 

After short-circuiting pins

and

,short-circuit pin

 

to start operation. 

/

 

  Red/white

 

 

遠隔操作切替信号

 

Remote-control operation 
switching signal 

④と⑧を短絡してリモート操作に移行させます

 

短絡するとタッチパネルの操作はできなくなります

 

Short-circuits the wires [4] and [8] to start remote operation. 

The AT panel is disabled while the wires [4] and [8] are 

short-circuited.

 

 

Yellow

 

 

能力レベル変更

 

Change capacity level 

⑦と⑧の間で、

0~5

Vの電圧を印加する事で能力レベル

を変更することが出来ます。

 

The capacity level can be changed by applying a 
voltage of 0 to 5V between pins

and

/

 

 

Yellow /white

 

 

Gnd

 

 

/

 

Black/White

 

 

運転圧力信号

 

Operation pressure signal 

出力信号

 

 

O

u

tp

u

s

ig

n

a

ls

 

現在の運転圧力を取り出します

 

Transfers the current operation output. 

アナログ信号

  Analog signal

1

5V

 

インピーダンス

  Impedance

  (≧

4.7

kΩ)

 

 

Red

 

 

風量不足信号

 

Insufficient airflow signal 

 

風量低下信号を取り出します 

Outputs an insufficient airflow signal. 

 

オープンコレクタ出力;

NPN 

Open collector output 

 

Green

 

 

運転出力信号

 

Operation output signal 

運転信号(ONランプ)を取り出します

 

Transfers the operation signal (ON indicator lamp). 

オープンコレクタ出力;

NPN 

Open collector output 

/

 

Green/White

 

 

圧力不足信号

 

Insufficient pressure signal

 

 

圧力不足信号を取り出します

 

Transfers the 

” 

Insufficient pressure

 

“ signal   

Outputs an insufficient pressure signal 

オープンコレクタ出力;

NPN 

Open collector output 

0

電圧

(DC

V)

 

能力レベル

 

Summary of Contents for CBA-1000AT2-HC-DSA-V1

Page 1: ...arker is an energy saving type clean box that realizes air technology in a compact body Please read this instruction manual thoroughly and handle this machine correctly so that you can use it safely f...

Page 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Page 3: ...AT panel 9 4 3 Remote connector 12 4 4 Confirmation before operation 13 4 5 Operation procedure 13 5 Remote Cable Sold Separately 14 5 1 Electrical circuit diagram 14 5 2 Color and signal of each wir...

Page 4: ...t outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electri...

Page 5: ...Dispose of the product properly as industrial waste 2 Confirmation and Preparation at Arrival After unpacking make sure that all parts are provided Contact our company immediately if parts are damage...

Page 6: ...Secondary filter CHF 2030 50 Active Carbon Cassette ACC 3220 100 Exhaust filter HEP 3220 69 Remove the sticker before use 1 1 1 The sticker is pasted to the filter when shipping it To prevent the zeo...

Page 7: ...econdary filter Protecting the circuit and the blower Active carbon cassette Absorbing the odor HEPA Exhaust HEPA filter Exhaust treatment 1 Primary filter Zeolite Cassette Filter Shaking motor Active...

Page 8: ...o match usage conditions the installed flange can be changed without having to use any tools Replacement flanges are sold separately 75 Removal method Turn the flange counterclockwise to remove it Tur...

Page 9: ...ilure Never adopt star burst connection that may cause voltage drop If voltage drop occurs longer time is required for startup 3 ON OFF 30 3 ON OFF It causes the trouble if ON OFF is frequently operat...

Page 10: ...to perform vibration manually after a short operating time cumulative time of less than 1 hour press the OFF button then press and hold the Manual Vibration button for 20 seconds Vibration continues...

Page 11: ...utomatically activates the vibration function Operating Pressure Indication Pa Indicates the current operating pressure level kPa 0 2 Pa 0 2 Pa When the equipment is not operating the pressure indicat...

Page 12: ...ours Indicator lamp Shaking 0 1hour After automatic shaking Off Hand operation shaking 1hour After automatic shaking Light up Automatic shaking 24 Some estimate of the number of shaking times for 24 h...

Page 13: ...icator lamp of AT panel lights AT ON Press the ON switch to start operation Confirm that abnormal sounds such as metallic sounds are not generated Confirm that the suction hose is connected securely 4...

Page 14: ...Temperature correction is not provided Reference example 3 5 6 33 0 1 F Attach a noise limiter Approximately 33 0 1 F to the output terminals Nos 1 2 and 3 When adding inductors such as relays 33 0 1...

Page 15: ...operation Red white Remote control operation switching signal Short circuits the wires 4 and 8 to start remote operation The AT panel is disabled while the wires 4 and 8 are short circuited Yellow Cha...

Page 16: ...the capacity level is changed the set level is stored in memory The set capacity level remains in memory even after the main power switch is turned off AT ON Lo Hi To change the capacity level using...

Page 17: ...ration 1 20 Auto operation shake off total up 1 hours After stopping the operation Auto moving for 20sec 20 Hand operation shake off After stopping the operation put on the manual shake off button for...

Page 18: ...disconnect the power plug from the electrical outlet before starting inspection Do not confuse the back and front of the filter The filter grid frame should be located on the exhaust side Release 2 s...

Page 19: ...sitioned at the center move the vibration arm to the end position before removing the guard or other parts 2 Remove 2 screws on both sides of the guard for shaking and get the guard off The guard for...

Page 20: ...ve carbon ACC 3220 100 ACC ACC plate 1 ACC Move up the ACC plate and remove active carbon 1 4 Release 4 snap locks and remove exhaust filter cover Exhaust filter cover 4 snap locks 2 Remove exhaust fi...

Page 21: ...it 2 Applicable fuse CBA 1000AT2 HC DSA V1 100 115V 10A 2 CBA 1000AT2 HC DSA V1 T 200V CE 220 240V 5A 2 Inspection item Frequency Description Filter case Before operation Is the case closed completely...

Page 22: ...filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status Start the operation 30 minutes later Fu...

Page 23: ...Copyright CHIKO AIRTEC CO LTD 2013 23 9 Indication of DANGER Labels 10 Electrical Circuit Diagram...

Page 24: ...y side when hose is connected to the suction port Before the zeolite adheres to the Primary filter After 2 5 2 7 m 3 min Machinery Directive EN ISO12100 1 2003 EN ISO 12100 2 2003 EN ISO14121 1 2007 E...

Page 25: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Reviews: