Fig. 4: the indoor PCB
Note
:
the above parameter is tested when there is the power in the PCB, so is the following
。
The voltage of the cross flow
fan feedback end will be
increased gradually from 0 to
+2.4VDC when turning on
the indoor unit
PTC1 resistance value
:
1
.
02K
Ω(
25
℃)
The limited current resistance
value
:
14.8 k
Ω
The voltage stabilizing diode
ZD1
、
ZD2 reference value
:
Forward
resisitance
:713
Ω
reverse resistance:
∞