Fig. 5
:
the outdoor PCB
Malfunction code
:
F2
(
the indoor temp sensor fault
)
Turn off the power
Take out the temperature sensor from the indoor PCB,
then check whether the indoor temperature sensor’s
resistance
is
normal.(the
range
of
normal
resistance
:1~40
K
Ω
)
N
Please replace it .when the indoor
temperature sensor has problem.
Y
Connect the sensor renewedly to the indoor PCB,
,
then
check the resistance between the sensor and indoor
PCB terminal. The normal resistance value is 0
Ω
N
The indoor temperature sensor adapter
connector breaks off, pls replace the
indoor PCB or restore the adapter
connector.
Y
The indoor PCB is bad
,
please change it
PTC1 resistance value
:
1
.
02K
Ω(
25
℃)
The
limited
current
resistance value
:
R54
:
0.76k
Ω
R58
:
2 k
Ω
Faulty cause
:
1
、
maybe
the indoor temp sensor’s
bnc connector plugs is loose or contact ill
;
2 、 the sensor is bad or
the
down-lead is
circuit-break、circuit-short
3、the indoor PCB’s hardware has been damaged
The voltage stabilizing diode
ZD1
、
ZD2 reference value
:
Forward resisitance :713
Ω
reverse
resistance:
∞
Please test the DC motor
end to N terminal voltage
value:
VCC-N
+15VDC、
P-N
+340VDC、
Vsp -N
0~+5VDC
Summary of Contents for CMV-50V9A-S
Page 1: ...DC Inverter Split Air Condition Unit SERVICE MANUAL ...
Page 6: ......
Page 8: ...The compressor s condensing pressure graph ...
Page 12: ...Capacity Correction Factor Due to Tubing Length One Way Cooling Heating ...
Page 13: ...Pressure Curve Suction Pressure Curve Discharge Pressure Curve ...
Page 18: ...5 The outdoor unit structure exploded view 5 1 The structure exploded view for CMV 50V9A S ...
Page 19: ......
Page 20: ...5 2 The structure exploded view for CMV V64T9AD ...
Page 21: ......