Installation Instructions
RPA Elite Series Projector Mount
7
RPM INSTALLATION
Threaded Pipe Installation
1.
Install ceiling plate and extension accessories
following installation instruction provided by
manufacturer.
WARNING:
IMPROPER INSTALLATION CAN
RESULT IN SERIOUS PERSONAL INJURY OR
DAMAGE TO EQUIPMENT! Structural members
MUST
be capable of supporting five times the
combined weight of all equipment being mounted.
2.
Align RPM with end of NTP pipe.
3.
Thread RPM up onto pipe by turning counter-
clockwise until hand tight.
2
1
3
Rough Alignment of RPM
1.
Turn RPM clockwise or counter-clockwise until
front of mount is facing target.
IMPORTANT ! :
When RPM is properly
positioned, the set screw access hole should be
pointing directly at target.
(see bottom detail in figure at left)
2.
Secure RPM to pipe by turning set screw until tight.
CAUTION:
DO NOT OVERTIGHTEN!
Overtightening of setscrew can damage threads on
pipe.
3.
Turn security screw using a Phillips screwdriver
until set screw cannot be seen through access hole
in RPM.
1
2
1
3
1
(A)
(A)