background image

MTMP1U

Installation Instructions

6

INSTALLATION

The MTMP1U mounts are designed to be mounted to a bare 8"
concrete or 8"x8"x16" concrete block wall; or 2" x 4"  wood studs
(16" on center) wall covered by drywall of 5/8" maximum
thickness. The MTMP1U has brackets which allow the TV to be
tilted.

Locate Mounting Site

WARNING:

IMPROPER INSTALLATION CAN LEAD TO

MOUNT FALLING CAUSING SEVERE PERSONAL INJURY
OR DAMAGE TO EQUIPMENT! It is the installers responsibility
to make certain the structure to which the mount is being
attached is capable of supporting five times the combined
weight of all components located on the mount, not to exceed
125 lbs (56.7 kg) for mounting to a single 2" x 4" wood stud; OR
200 lbs (90.7 kg) for mounting to dual 2" x 4" wood studs or
concrete.

NOTE:

Proceed to either the

Installing to a Wood Stud Wall

section or the

Installing to a Concrete Wall

section.

Installing to a Wood Stud Wall

1.

Determine the center of the TV screen, and where it should
be located on the wall.

WARNING:

The MTMP1U is designed to be mounted to

either one or two 2" x 4" wood studs (16" on center).

2.

Locate the closest studs to the left and right of the selected
location.

3.

Line up the notches on mount (Z) with center of screen
marking to determine vertical center. (See Figure 1)

Figure 1

4.

Measure up 8" (203.2mm) from the center point to mark
location of the upper mounting slots. (See Figure 1)

5.

Using a level, mark the wall on each stud to attach the
mount through the upper mounting slots. (See Figure 2)

6.

Drill one 7/32" (5.5mm) pilot hole in each stud.

7.

Partially install two 5/16 x 2-1/2" flanged lag bolts (N) into
pilot holes but do not tighten to wall.

8.

Hang mount (Z), aligning upper mounting slots over lag
bolts and adjust side-to-side for proper location.

9.

Place one slotted washer (Q) over each flanged lag bolt.
(See Figure 2)

10. Tighten lag bolts to secure mount (Z) to wall at upper

mounting slots.

Figure 2

11. Mark the attachment points for the lower mounting slots,

making sure the attachment points are located on the studs.
(See Figure 10)

12. Drill 7/32" (5.5mm) pilot holes at markings for lower

mounting holes. (See Figure 10)

13. Use two 5/16 x 2-1/2" flanged lag bolts (N) and two 5/16"

slotted washers (Q) to attach the mount to the wall through
the lower mounting holes. (See Figure 10)

14. Slide rails to approximate center of screen location.

15. Proceed to

Locking Rails

 section.

Center of screen

  8”

Vertical center
of mount

[203.2mm]

(Z)

4

11

12

5

6

(Q) x 2

7

10

(N) x 2

(CC)

9

(Q) x 2

13

(N) x 2

13

NOTE: Circled areas indicate mounting holes for
            single stud mounting application.

Summary of Contents for MTMP1U

Page 1: ... S T R U C T I O N S FUSION PORTRAIT MEDIUM TILT MOUNT Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description MTMP1U ...

Page 2: ...taller s responsibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight ...

Page 3: ...ES MILLIMETERS 7 00 177 8 RAILS CAN BE SLID LEFT OR RIGHT FOR OFFSET 0 34 8 7 1 MAXIMUM MOUNTING PATTERN IS 18 8 477 5 mm WITHOUT REVERSING UPRIGHTS 2 MAXIMUM MOUNTING PATTERN IS 22 5 571 5 mm WITH REVERSING UPRIGHTS 3 FOR RECESSED APPLICATIONS MINIMUM VERTICAL LIFT FOR HOOK ENGAGEMENT IS 75 19 mm DIMENSIONS INCHES MILLIMETERS ...

Page 4: ... fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren...

Page 5: ...x12mm H 4 M6x20mm Universal Hardware Kit I 4 M6x25mm K 4 J 4 M8x12mm M8x20mm L 4 M8x30mm MA 8 Nesting MB 4 Universal washer Wall Mounting Hardware Kit N 4 5 16 x 2 1 2 P 4 UX10x60mm Q 4 Slotted washer R 1 1 8 S 1 3 16 U 2 3 8 16 x 3 4 Mount Hardware Kit T 4 1 4 20 x 3 4 V 2 1 4 20 x 1 W 2 1 4 20 X 1 Y 1 left right Interface brackets Z 1 spacer Wall mount Included in hardware box Included in hardwa...

Page 6: ...e notches on mount Z with center of screen marking to determine vertical center See Figure 1 Figure 1 4 Measure up 8 203 2mm from the center point to mark location of the upper mounting slots See Figure 1 5 Using a level mark the wall on each stud to attach the mount through the upper mounting slots See Figure 2 6 Drill one 7 32 5 5mm pilot hole in each stud 7 Partially install two 5 16 x 2 1 2 fl...

Page 7: ...st side to side for proper location 9 Place one slotted washer Q over each flanged lag bolt See Figure 3 10 Mark the attachment points for the lower mounting slots See Figure 3 11 Drill 3 8 x 3 1 2 9 5mm x 88 9mm pilot holes at markings for lower mounting holes See Figure 3 12 Install an anchor P into each pilot hole using a hammer making sure that the anchor is flush with the wall 13 Use two 5 16...

Page 8: ... M and attach brackets to back of screen See Figure 5 IMPORTANT Dual Stud Installation Only If M4 fasteners are used to attach brackets to back of screen the weight of the screen may NOT exceed 150 lbs 68 0 kg NOTE The nesting spacers MA may be used separately or put two together in different configurations to create different size spacers See Figure 6 Figure 6 Switching Upright Brackets Optional ...

Page 9: ... of the bracket f Switch the right interface bracket to the left side of the wall mount g Repeat Steps 3c through 3f with the left upright bracket Figure 8 Attaching Display to Wall Mount NOTE NEVER place both interface brackets X and Y to one side of the wall mount center line See Figure 9 NOTE Do NOT allow both interface brackets X and Y to be located on same side of wall mount See Figure 9 Figu...

Page 10: ...gnet to mount so it does not extend beyond bottom of screen See Figure 10 Adjustments Horizontal Adjustment 1 The wall mount may be adjusted side to side at the point s of attachment See Figure 11 Figure 11 2 The screen may be adjusted along rails side to side NOTE NEVER place both interface brackets X and Y to one side of the wall mount center line See Figure 9 NOTE Do NOT allow both interface br...

Page 11: ...ure 13 4 Tighten interface bracket knob Figure 13 Locking Interface Brackets Optional 1 Lock interface brackets onto mount rails using one 3 8 16 x 3 4 set screw U on each interface bracket See Figure 14 Figure 14 Locking Mount Optional 1 Add padlock not included to interface bracket to complete security See Figure 19 NOTE The padlock maximum shackle diameter is 5 16 7 9 mm Figure 15 Latch in CLOS...

Page 12: ... com 01 15 USA International A 6436 City West Parkway Eden Prairie MN 55344 P 800 582 6480 952 225 6000 F 877 894 6918 952 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 ...