background image

MSP-TEQ9

Installation Instructions

2

DISCLAIMER

Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.

Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.

  IMPORTANT SAFETY INSTRUCTIONS

WARNING:

A WARNING alerts you to the possibility of

serious injury or death if you do not follow the instructions.

CAUTION:

A CAUTION alerts you to the possibility of

damage or destruction of equipment if you do not follow the
corresponding instructions.

WARNING:

Failure to read, thoroughly understand, and

follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty!  It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.

WARNING:

Failure to provide adequate structural strength

for this component can result in serious personal injury or
damage to equipment!  It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component. The wall to which the mount is being attached
may have a maximum drywall thickness of 5/8" (wood stud or
concrete installations).

WARNING:

Exceeding the weight capacity can result in

serious personal injury or damage to equipment!  It is the
installer’s responsibility to make sure the combined weight of
all components located on the MSP-TEQ9 does not exceed
125 lbs (56.7 kg).

WARNING:

Use this mounting system only for its intended

use as described in these instructions. Do not use
attachments not recommended by the manufacturer.

WARNING:

Never operate this mounting system if it is

damaged. Return the mounting system to a service center for
examination and repair.

WARNING:

Do not use this product outdoors.

IMPORTANT ! :

The MSP-TEQ9 has been designed to be

mounted onto either a 2" x 4" wood stud wall, an 8" concrete
wall, or an 8" x 8" x 16" concrete block wall.

--SAVE THESE INSTRUCTIONS--

Summary of Contents for MSP-TEQ9

Page 1: ... T R U C T I O N S Telescoping Leg Interactive Whiteboard Mount with Hanger Bracket German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description MSP TEQ9 ...

Page 2: ...l injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to whi...

Page 3: ...Installation Instructions MSP TEQ9 3 DIMENSIONS 1 00 25 4 DIMENSIONS INCHES MILLIMETERS ...

Page 4: ... Fastener Apretar elemento de fijación Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Loosen Fastener Aflojar elemento de fijación Befestigungsteil lösen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phill...

Page 5: ...ht assembly K 1 Wall assembly L 2 Wall bracket cover M 2 Sliding cover S 2 4 x 255 x 0625 N 2 Adjustable leg G 4 Isolation washer H 4 1 4 20 x 1 J 4 500x 320x 425 P 2 Alternate foot T 10 75x 265x1 125 Q 8 M4 x 08mm R 10 M6 x 40mm Knob V 2 1 4 U 2 AF6 toggler W 2 1 4 20 x 2 1 2 X 2 1 4 20 x 1 3 4 Y 2 1 4 20 not used not used not used not used Z 2 Whiteboard hanger bracket not used not used not used...

Page 6: ...acers T See Figure 1 NOTE Three knobs and spacers should be used on each leg assembly If necessary two knobs may be used at a minimum 4 Repeat Steps 1 through 3 on the other upright assembly D Figure 1 Assembling Brackets to Legs 1 Lay two upright assemblies D on floor along side of whiteboard 2 Determine where to fasten upper whiteboard hanger bracket Z to upright assemblies D 3 Fasten one whiteb...

Page 7: ...osest 2 x 4 wood stud to the left and right of the selected location NOTE The two wall brackets on the wall assembly K must be mounted a minimum of 16 apart or a maximum of 42 apart 3 Using a level mark the wall on each stud above existing chalkboard through top mounting hole in the wall assembly K See Figure 5 4 Drill one 1 8 pilot hole in each stud See Figure 5 5 Use two 1 4 20 x 2 1 2 lag bolts...

Page 8: ...K to anchors in wall See Figure 6 Attaching Upright Assemblies to Wall Assembly 1 Hook upright assemblies D with attached whiteboard hanger brackets Z onto the wall assembly K See Figure 7 2 Move the slide nut so that it is aligned with one upright D See Figure 7 3 Fasten upright in place using one 1 4 20 x 3 8 button head cap screw F and one 4 x 255 x 0625 nylon spacer S into slide nut See Figure...

Page 9: ...wer whiteboard hanger bracket Z match up with mounting holes in lower tabs of whiteboard See Figure 9 3 Tighten all knobs See Figure 9 4 Fasten bottom of whiteboard to lower whiteboard hanger bracket Z using two M6 x 12mm Phillips screws AA through tabs at bottom of whiteboard into front of whiteboard hanger bracket Z See Figure 9 Figure 9 2 2 3 x 6 2 AA x 2 Z view behind whiteboard 4 whiteboard t...

Page 10: ...essary adjustments BEFORE completing attachment to wall NOTE The lower part of the MSP TEQ9 must be attached to the wall using the correct hardware for the wall type It may be attached to a wood stud wall or a concrete or concrete block wall Proceed to appropriate section for instruction Wood Stud Wall 1 Mark the wall over wood stud through the adjustable leg N at the lower end of each upright ass...

Page 11: ... 6 Use one 1 4 20 x 2 1 2 lag bolt W and one 1 4 flat washer V to attach adjustable leg N to anchor in wall See Figure 13 7 Repeat Steps 2 through 6 for other upright assembly Adding Covers 1 Open the lower flaps of the wall bracket cover L outward See Figure 14 2 Slide the cover downward hooking the top of the wall bracket covers L onto the tabs on top of wall assembly brackets See Figure 14 3 Sl...

Page 12: ...nds P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 MSP TEQ9 Installation Instructions Chief Manufacturing a products division of Milestone AV Technologies 8800 002315 Rev00 2013 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 02 13 ...