ASSEMBLY AND INSTALLATION
Preparing Wall Bracket
1.
Remove kiosk from the packaging and place on a flat surface. (See Figure 1)
2.
Open hinged frame to 90°.
3.
Keeping the hinged frame at 90° slide the hinged frame about 1 inch towards top of kiosk until hinge pins clear the hinges, and
move the hinged frame away from the wall bracket. (See Figure 1)
Figure 1
3
2
Hinged frame
Wall bracket
NOTE:
The kiosks ship with the Lever Lock™ internal
management system shelf already in place. The shelf
may be removed to add components as required, and
then reinstalled. (See instructions included with the
shelf.)
IMPORTANT ! :
The kiosks ship with the hinge located
on the left side. The hinge location may be switched, if
required, for installation or service.
Before beginning
the installation
, decide on which side the hinge should
be located and, if you require the kiosk be hinged on the
right side, switch the hinge
before
completing any other
installation steps. See
Switching Hinge Location
section in
Appendix
.
Locate Mounting Site
WARNING:
IMPROPER INSTALLATION CAN LEAD TO
MOUNT FALLING CAUSING SEVERE PERSONAL INJURY
OR DAMAGE TO EQUIPMENT! It is the installers responsibility
to make certain the structure to which the mount is being
attached is capable of supporting five times the combined
weight of all components located on the mount:
•
LW46/47/48UxP Models
: 100 lbs (45.4 kg)
•
LW49/50/55UxP Models:
125 lbs (56.7 kg)
Installing Wall Bracket
The LW
46/47/48/49/50/55UxP wall kiosk mounts are designed
to be mounted to:
•
a bare 8" concrete or 8"x8"x16" concrete block wall; or
•
a 2" x 4" wood studs (16" on center minimum) wall with
a maximum drywall thickness of 5/8"; or
•
a steel stud (16" on center minimum to 24" on center
maximum) wall with a maximum drywall thickness of 5/8".
Table 1: Fastener Inform
WALL
TYPE
PILOT
HOLE
FASTENERS (see PARTS
drawing)
Steel
stud /
Wood
stud
1/2"
7/32"
- 1/4-20 x 1-3/4" Phillips screw
(
AD
)
- 1/4" washer (
AE
)
- 1/4-20 Snap toggler (
AC
)
- 5/16 x 2-1/2" hex head lag (
AA
)
- 5/16" washer (
AB
)
Concrete
5/16 x 3-1/4"
- 5/16 x 2-1/2" hex head lag (
AA
)
- 5/16" washer (
AB
)
- Fischer Anchor UX10x60R
(AF)