background image

 LW46/47/48/49/50/55UxP

Installation Instructions

2

DISCLAIMER

Milestone AV Technologies and its affiliated corporations and 
subsidiaries (collectively “Milestone”), intend to make this 
manual accurate and complete. However, Milestone makes no 
claim that the information contained herein covers all details, 
conditions or variations, nor does it provide for every possible 
contingency in connection with the installation or use of this 
product. The information contained in this document is subject 
to change without notice or obligation of any kind. Milestone 
makes no representation of warranty, expressed or implied, 
regarding the information contained herein. Milestone assumes 
no responsibility for accuracy, completeness or sufficiency of 
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies. 
All rights reserved.
Lever Lock™ is a trademark of Middle Atlantic Products, Inc. All 
rights reserved.

DEFINITIONS

MOUNTING SYSTEM: 

A MOUNTING SYSTEM is the 

primary Chief product to which an accessory and/or component 

is attached.

ACCESSORY: 

AN ACCESSORY is the secondary Chief 

product which is attached to a primary Chief product, and may 

have a component attached or setting on it.

COMPONENT: 

A COMPONENT is an audiovisual item 

designed to be attached or resting on an accessory or mounting 

system such as a video camera, CPU, screen, display, 

projector, etc.

WARNING:  

A WARNING alerts you to the possibility of 

serious injury or death if you do not follow the instructions.

CAUTION:  

A CAUTION alerts you to the possibility of 

damage or destruction of equipment if you do not follow the 

corresponding instructions.

 IMPORTANT SAFETY INSTRUCTIONS

WARNING:  

Failure to read, thoroughly understand, and 

follow all instructions can result in serious personal injury, 
damage to equipment, or voiding of factory warranty! It is the 
installer’s responsibility to make sure all mounting systems 
are properly assembled and installed using the instructions 
provided.

WARNING:  

Failure to provide adequate structural strength 

for this mounting system can result in serious personal injury 
or damage to equipment! It is the installer’s responsibility to 
make sure the structure to which this mounting system is 
attached can support five times the combined weight of all 
equipment. Reinforce the structure as required before 
installing the mounting system. 

WARNING:  

Exceeding the weight capacity can result in 

serious personal injury or damage to equipment! It is the 
installer’s responsibility to make sure the combined weight of 
all components attached to mounting system does not 
exceed:

LW46/47/48UxP Models

: 100 lbs (45.4 kg)

LW49/50/55UxP Models

: 125 lbs (56.7 kg)

WARNING:  

Use this mounting system only for its intended 

use as described in these instructions. Do not use 
attachments not recommended by the manufacturer.

WARNING:  

Never operate this mounting system if it is 

damaged. Return the mounting system to a service center for 
examination and repair.

WARNING:  

Do not use this mounting system outdoors.

IMPORTANT ! : 

The LW46/47/48/49/50/55UxP portrait wall 

kiosks are designed to be mounted to an: 

a bare 8" concrete or 8"x8"x16" concrete block wall; or

a 2" x 4" wood studs (16" on center minimum) wall with 

a maximum drywall thickness of 5/8"; or

a steel stud (16" on center minimum to 24" on center 

maximum) wall with a maximum drywall thickness of   

5/8".

NOTE:  

The kiosks have an adjustable depth of 3" to 5".

--SAVE THESE INSTRUCTIONS--

Summary of Contents for LW46UxP

Page 1: ... T I O N S 46 47 48 49 50 55 Portrait Wall Kiosks Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description LW46 47 48 49 50 55UxP ...

Page 2: ...w the corresponding instructions IMPORTANT SAFETY INSTRUCTIONS WARNING Failure to read thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all mounting systems are properly assembled and installed using the instructions provided WARNING Failure to provide adequat...

Page 3: ...llation Instructions LW46 47 48 49 50 55UxP 3 DIMENSIONS 46 50 1181 1 27 50 698 5 22 50 571 5 LW46UxP DIMENSIONS INCHES MILLIMETERS 46 50 1181 1 27 50 698 5 23 00 584 2 LW47UxP DIMENSIONS INCHES MILLIMETERS ...

Page 4: ...LW46 47 48 49 50 55UxP Installation Instructions 4 DIMENSIONS continued 46 50 1181 1 27 50 698 5 23 50 596 9 LW48UxP DIMENSIONS INCHES MILLIMETERS LW49UxP DIMENSIONS INCHES MILLIMETERS ...

Page 5: ...Installation Instructions LW46 47 48 49 50 55UxP 5 DIMENSIONS continued LW50UxP DIMENSIONS INCHES MILLIMETERS 54 25 1378 0 32 50 825 5 26 84 681 8 LW55UxP DIMENSIONS INCHES MILLIMETERS LW55UxP ...

Page 6: ...gonale Zeskantsleutel Clé à tête hexagonale 7 32 wood studs 2 1 2 5 32 security 5 16 concrete 1 2 steel studs included Hardware Bag Wall Hardware Hardware Bag Monitor Interface Hardware Hardware Bag Security Swap Hardware AA 8 5 16 x 2 1 2 AB 8 5 16 AC 4 1 4 20 SnapToggle AD 4 AE 4 1 4 20 x 1 3 4 1 4 BA 4 M4 x 12mm BD 4 M5 x 12mm BG 4 M6 x 12mm BJ 4 M8 x 12mm BB 4 M4 x 25mm BC 4 M4 x 50mm BE 4 M5 ...

Page 7: ...completing any other installation steps See Switching Hinge Location section in Appendix Locate Mounting Site WARNING IMPROPER INSTALLATION CAN LEAD TO MOUNT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT It is the installers responsibility to make certain the structure to which the mount is being attached is capable of supporting five times the combined weight of all components loc...

Page 8: ...far apart as possible See Figure 2 2 Drill one pilot hole see Table 1 for size at both locations marked in Step 1 See Figure 2 and follow fastener information appropriate for wall type located in Table 1 IMPORTANT Refer to Fastener Installation Methods located in Appendix at end of Installation Instructions for details on installing product into various wall types Figure 3 3 Partially install fast...

Page 9: ... be sure to use longer screws of the same diameter 4 Select screw diameter by examining hardware BA BL and comparing with mounting holes on flat panel 5 Select spacers Spacers are NOT required if mounting holes are not recessed and hinged frame can lay flat against flat panel Spacers BM BN ARE required if mounting holes are recessed or if protrusions prevent hinged frame from laying flat Spacers m...

Page 10: ... adjustments Figure 8 9 Tighten thumb nuts over threaded studs in four locations on the hinged frame See Figure 8 10 Replace and fasten four Phillips screws which were removed in Step 1 OR replace the removed screws with four 10 24 x 2 3 4 Phillips head screws CD to allow for a larger depth adjustment of the outer frame See Figure 8 11 Carefully lift using two people the outer frame with attached ...

Page 11: ...ket See Figure 11 3 DISCARD the four fasteners from these hinge parts Figure 11 4 Remove and SAVE lift off hinge and hinge spacer plate from two locations on swing door assembly See Figure 12 5 DISCARD the four fasteners from these hinge parts Figure 12 1 Remove and SAVE fasteners noted all parts and Wall bracket 2 Remove and SAVE two hinges Wall bracket Hinge 4 Remove and SAVE two hinges and hing...

Page 12: ...sten in place with four two each hinge NEW 10 32 x 3 4 button head cap screws CB See Figure 13 Figure 13 8 Move the lift off hinges to the right side of the wall bracket See Figure 14 9 Fasten in place with four two each hinge NEW 10 32 x 5 16 button head cap screws CC See Figure 14 Figure 14 Lift off hinge Hinge spacer plate 7 CB x 4 Wall bracket 9 CC x 4 Lift off hinge ...

Page 13: ...on in Step 1 by fastening it onto the top of the latch section See Figure 15 13 Re install outside latch using fastener removed in Step 1 See Figure 15 14 Re install inside latch See Figure 15 a Place spring on top of horizontal tab and compress spring slightly b Place latch over spring lining up tabs on latch with slots in wall bracket a Fasten latch in place with button head cap screw and washer...

Page 14: ...before proceeding with Steel Studs installation to ensure installation site meets requirements The drywall must have a minimum thickness of 1 2 1 Hold metal channel on anchor AC flat alongside plastic straps and slide channel through hole See Figure 18 Figure 18 2 Holding plastic straps on anchor AC pull anchor away from wall until channel rests flush behind wall making sure anchor channel is posi...

Page 15: ...tallation Figure 22 Steel Stud 2 x 4 25ga minimum FRONT There must be a minimum of 1 7 8 48mm clearance inside wall 16 or 24 on center Studs If back side of wall is unfinished to a minimum of one stud left Stud type and structural strength must conform to the North American Specification for the Drywall 1 2 minimum Drywall Thickness Both Sides of Stud See Warning statement on page 2 Design of Cold...

Page 16: ...52 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 Chief a products division of Milestone AV Technologies 8800 003033 Rev00 2018 Milestone AV Technologies www milestone com 07 18 ...