background image

Installation Instructions

 LW46/47/48/49/50/55UxP

9

IMPORTANT ! : 

Attaching the wall bracket requires a 

minimum of 8 wall fasteners. For installation in a wood or 

steel stud applications, the snap toggles are required 

near the edge of the wall bracket hinge side if the hinge 

side is not fastened to a stud. (See Figure 4) and (See 

Figure 5)

Figure 4

3.

Partially install fasteners into wall, but do not completely 

tighten to wall.

4.

Hang wall bracket, aligning upper mounting slot clearance 

holes over fasteners and adjust side-to-side for proper 

location. (See Figure 4)

5.

Tighten fasteners to secure wall bracket to wall at upper 

mounting slots.

6.

Drill six remaining pilot holes (see Table 1 for size) at 

attachment locations and follow fastener information 

(appropriate for wall type) located in Table 1. (See Figure 4)

7.

Tighten six fasteners to secure wall bracket to wall at middle 

and lower mounting slots.

8.

For Wood and Steel Stud walls: 

Insert four snap toggles 

and related fasteners into hinge side of wall bracket. (See 

Figure 5)

IMPORTANT ! : 

Refer to 

Fastener Installation Methods 

(located in 

Appendix 

at end of Installation Instructions) 

for details on installing snap toggles and related 

fasteners into various wall types.

 

Figure 5

Attaching Flat Panel

1.

Remove and 

SAVE

 four Phillips screws, loosen four thumb 

nuts and remove hinged frame from swing door. (See 

Figure 6)

Figure 6 

5

6

x 2

7

[24" on-center attachment

shown as example only]

Clearance

holes

Mounting

slots

8

Insert snap-toggles at arrows 

[For Wood and Steel Stud Walls Only]

1

x 4

  Thumb

     nut

1

Hinged

frame

Outer

frame

Summary of Contents for LW46U P Series

Page 1: ...T I O N S 46 47 48 49 50 55 Portrait Wall Kiosks Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Prod...

Page 2: ...and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all mounting systems are properl...

Page 3: ...lation Instructions LW46 47 48 49 50 55UxP 3 DIMENSIONS 46 50 1181 1 27 50 698 5 22 50 571 5 LW46UxP DIMENSIONS INCHES MILLIMETERS 46 50 1181 1 27 50 698 5 23 00 584 2 LW47UxP DIMENSIONS INCHES MILLIM...

Page 4: ...LW46 47 48 49 50 55UxP Installation Instructions 4 DIMENSIONS continued 46 50 1181 1 27 50 698 5 23 50 596 9 LW48UxP DIMENSIONS INCHES MILLIMETERS LW49UxP DIMENSIONS INCHES MILLIMETERS...

Page 5: ...Installation Instructions LW46 47 48 49 50 55UxP 5 DIMENSIONS continued LW50UxP DIMENSIONS INCHES MILLIMETERS 54 25 1378 0 32 50 825 5 26 84 681 8 55U DIMENSIONS INCHES MILLIMETERS LW55UxP...

Page 6: ...nale Zeskantsleutel Cl t te hexagonale 7 32 wood studs 2 1 2 5 32 security 5 16 concrete 1 2 steel studs included Hardware Bag Wall Hardware Hardware Bag Monitor Interface Hardware Hardware Bag Securi...

Page 7: ...tall the panel slide the panel end without latches sideways into the slots on one side of the wall bracket opening Pivot panel in and slide it sideways toward the slots on opposite side of the wall br...

Page 8: ...stud wall mount the hinge side of kiosk as close as possible to a stud For concrete walls use a level and mark the two uppermost locations for attachment as far apart as possible to provide maximum s...

Page 9: ...or size at attachment locations and follow fastener information appropriate for wall type located in Table 1 See Figure 4 7 Tighten six fasteners to secure wall bracket to wall at middle and lower mou...

Page 10: ...BO if required hinged frame spacer BM BN if required into flat panel mounting hole Do NOT thread screw into hole at this time IMPORTANT The M8 screws do NOT require a washer Use the universal washer...

Page 11: ...Lower swing door to engage hinge pins into hinges See Figure 10 NOTE Some resistance is normal when the hinge pins drop into the hinges Figure 10 14 Close swing door and add 10 24 x 3 8 button head s...

Page 12: ...racket See Figure 13 3 DISCARD the four fasteners from these hinge parts Figure 13 4 Remove and SAVE lift off hinge and hinge spacer plate from two locations on swing door See Figure 14 5 DISCARD the...

Page 13: ...n place with four two each hinge NEW 10 32 x 3 4 button head cap screws CB See Figure 15 Figure 15 8 Move the lift off hinges to the right side of the wall bracket See Figure 16 9 Fasten in place with...

Page 14: ...n in Step 1 by fastening it onto the top of the latch section See Figure 17 13 Re install outside latch using fastener removed in Step 1 See Figure 17 14 Re install inside latch See Figure 17 a Place...

Page 15: ...efore proceeding with Steel Studs installation to ensure installation site meets requirements The drywall must have a minimum thickness of 1 2 1 Hold metal channel on anchor AC flat alongside plastic...

Page 16: ...allation Figure 24 Steel Stud 2 x 4 25ga minimum FRONT There must be a minimum of 1 7 8 48mm clearance inside wall 16 or 24 on center Studs If back side of wall is unfinished to a minimum of one stud...

Page 17: ...Installation Instructions LW46 47 48 49 50 55UxP 17...

Page 18: ...LW46 47 48 49 50 55UxP Installation Instructions 18...

Page 19: ...Installation Instructions LW46 47 48 49 50 55UxP 19...

Page 20: ...2 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P...

Reviews: