EGX-SF2

Installation Instructions

8

5.

Replace the outlet box into the EGX-SF2 housing. (See
Figure 4)

6.

Rotate outlet box clockwise until it is in proper position to be
secured to the EGX-SF2 housing. (See Figure 4)

7.

Tighten two Phillips screws to secure outlet box to EGX-
SF2 housing. (See Figure 4)

Figure 4

8.

Install two clips (C) onto either side of EGX-SF2 housing.
(See Figure 5)

Figure 5

9.

Insert EGX-SF2 housing into drywall opening. (See Figure
6)

Figure 6

10. Tighten screws on the two drywall clamps so that they are

locked in place against the drywall, and not laying flat
against the EGX-SF2. (See Figure 7)

Figure 7

11. Remove Phillips flat head screw and locking washer from in

between outlets. (See Figure 7)

12. Install faceplate (B) onto EGX-SF2 using one Phillips flat

head screw and locking washer removed in Step 11. (See
Figure 8)

NOTE:

Make sure LED light on outlet box lines up with hole

location on faceplate (B). (See Figure 8)

Figure 8

Outlet Box Use

NOTE:

The “PROTECTED” light indicates that the surge

protection circuitry is active and operational. (See
Figure 9)

Figure 9

6

7

x2

5

(C) x 2

9

9

Wall
Clamp

10

x 2

(Front View)

Wall

Clamp

Wall

Clamp

11

12

(removed screw and

(B)

LED light

washer) x 1

“PROTECTED”

indicator light

Summary of Contents for EGX-SF2

Page 1: ...truções de Instalação Istruzioni di installazione Installatie instructies Instructions d installation Power Conditioned Outlet Box Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description EGX SF2 ...

Page 2: ... the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT DANGER TO REDUCE THE RISK OF ELECTRIC SHOCK 1 Always turn off power at source before installing the outlet WARNING TO REDUCE THE RISK OF BURNS FIRE ELECTRIC SHOCK OR INJURY TO PERSONS Always turn off power at source before ...

Page 3: ...are il fissaggio Bevestiging losdraaien Desserrez les fixations Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar Bohrloch Fazer furo Praticare ...

Page 4: ...EGX SF2 Installation Instructions 4 DIMENSIONS ...

Page 5: ...REQUIRED FOR INSTALLATION PARTS A 1 B 1 D 1 10 32 x 3 8 Earthing symbol IEC 60417 No 5019 affixed adjacent to grounding terminal Grounding screw and washer installed at factory Outlet box Outlet cover C 2 Clip E 1 New work clip F 2 12 24 x 3 8 ...

Page 6: ...t 1 Rule 10 906 Bonding conductor connection to circuits and equipment 6 A bonding jumper shall be installed to connect the bonding conductor to the grounding terminal of a receptacle and in such a manner that disconnection or removal of the receptacle will not interfere with or interrupt grounding continuity 7 In the case of metallically enclosed systems where the grounding path is provided by th...

Page 7: ...shall avoid unnecessary bends NOTE An insulated grounding conductor that is identical in size and insulation material and thickness to the grounded and ungrounded circuit supply conductors except that it is green with or without one or more yellow stripes is to be installed as part of the circuit that supplies the outlet Refer to Table 250 122 of the National Electrical Code regarding the appropri...

Page 8: ...t they are locked in place against the drywall and not laying flat against the EGX SF2 See Figure 7 Figure 7 11 Remove Phillips flat head screw and locking washer from in between outlets See Figure 7 12 Install faceplate B onto EGX SF2 using one Phillips flat head screw and locking washer removed in Step 11 See Figure 8 NOTE Make sure LED light on outlet box lines up with hole location on faceplat...

Page 9: ...n the building wiring attach it separately to the green yellow isolated ground wire on box If there is no separate green yellow isolated ground wire connect green ground wire to both green yellow isolated ground wire and green box ground wire on box NOTE The grounding conductors serving this outlet are to be connected to earth ground at the service equipment or other acceptable building earth grou...

Page 10: ...that it is locked in place against the drywall and not laying flat against the EGX SF2 See Figure 14 13 Remove Phillips flat head screw and locking washer from in between outlets See Figure 15 Figure 15 14 Install faceplate B onto EGX SF2 using one Phillips flat head screw and locking washer removed in Step 5 See Figure 16 NOTE Make sure LED light on outlet box lines up with hole location on facep...

Page 11: ...Installation Instructions EGX SF2 11 ...

Page 12: ...e com 08 17 USA International A 6436 City West Parkway Eden Prairie MN 55344 P 800 582 6480 952 225 6000 F 877 894 6918 952 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 ...

Reviews: