Installation Instructions
CMS490
5
PREPARING FOR INSTALLATION
Installation Requirements
The CMS490 has been designed to be mounted recessed into
a suspended ceiling consisting of 2’ x 2’ ceiling tiles and
secured by a WireVice system.
Preparing Framework
1.
Attach track clips [2 left (A), 2 right (B)] one at each corner
of the CMS490 frame (N) using one 06-32 x 1/2" Phillips flat
head screw (F) on each clip. (See Figure 1)
Figure 1
Installing CMS490 Framework
1.
Remove one 2 ft x 2 ft tile from ceiling.
2.
Insert CMS490 frame (N) with attached brackets into the
empty ceiling space. (See Figure 2)
3.
Set CMS490 frame (N) over top of ceiling framework,
hooking each track clip (A and B) onto the ceiling
framework. (See Figure 3)
4.
Secure CMS490 frame (N) to ceiling framework using one
10-24 x 1/2" Phillips head screw (D) through each track clip
(D) at each corner. (See Figure 3)
Figure 2
Figure 3
(F) x 4
(A)
(A)
(B)
(B)
(N)
1
Ceiling
Framework
2
(N)
Ceiling
Framework
3
(B)
4
(D) x 4
(N)
(N)