TIL1X2AA / TIL1X3AA / TIL1X4AA / TILVABAA
Installation Instructions
12
Steel Stud
IMPORTANT ! :
See
Site Requirements for Steel Stud
Installation
section before proceeding with Steel Studs
installation to ensure installation site meets requirements!
The drywall must have a minimum thickness of 1/2"!
1.
Hold metal channel on anchor flat alongside plastic straps
and slide channel through hole. (See Figure 21)
Figure 21
2.
Holding plastic straps on anchor, pull anchor away from wall
until channel rests flush behind wall making sure anchor
channel is positioned vertically on drywall, or steel stud (if
present). (See Figure 22)
3.
Slide plastic cap on anchor towards wall until flange of cap
is flush with wall. (See Figure 22)
Figure 22
4.
Snap off plastic straps on anchor at wall by pushing side to
side, snapping off straps level with flange of plastic cap.
(See Figure 23)
Figure 23
5.
Line up anchor with attachment point.
6.
Insert 1/4-20 x 1-3/4" Phillips pan head screw through 1/4"
washer, corresponding mounting hole in wall bracket and
into anchor, and tighten until flush against wall bracket. DO
NOT over tighten! (See Figure 24)
Figure 24
Drywall
Plastic straps
1
Plastic cap
Drywall
Anchor metal channel
3
Steel stud
(side view)
2
(if present)
Plastic straps
Drywall
Anchor metal channel
Plastic cap
4
Steel stud
(side view)
(if present)
Drywall
Anchor metal channel
Phillips
6
Steel stud
Washer
(side view)
Wall bracket
(if present)
screw