Page 19
SKU 95189
For technical questions, please call 1-800-444-3353.
REV 09a
iNSPEcTiON, MAiNTENANcE, AND cLEANiNG
cAuTiON! Always make sure the Engine Power Switch (2) is in its “OFF” position.
1.
Disconnect the spark plug wire from the engine and allow sufficient time for the
Engine and Generator to completely cool before performing any inspection, main-
tenance, or cleaning.
Before each use,
2.
inspect the general condition of the Generator and Engine. Check for
loose screws, misalignment or binding of moving parts, cracked or broken parts, loose hose
connections, and any other condition that may affect the safe operation of the Generator
and Engine. If abnormal noise or vibration occurs, have the problem corrected before
further use.
Do not use damaged equipment.
Follow all maintenance procedures as outlined in the
3.
Engine Maintenance Schedule
below at the specified intervals. In addition, observe the following details:
Before each use:
check to make sure the Engine’s oil level is adequate. If necessary, fill
the Engine’s Crankcase until the oil level is even with the Oil Fill Hole.
Before each use:
with a soft brush, sloth, or vacuum, remove all debris from the Generator
and Engine. Then, use a premium quality, lightweight machine oil to lubricate all moving
parts.
After the inital 20 hours of use and every 100 hours of use thereafter:
drain the old
Engine oil and replace with approximately 3/4 (0.63) quart of a high quality SAE 10W-30
grade engine oil.
Alway keep fuel tank capped, even when empty, to prevent rainwater, dirt and debris from
4.
getting into the fuel tank.