Air Chicago
TECHNICAL
SPECIFICATIONS
07/08/09
Folder
6500-003D
App:GW
Specifications subject to change without notice.
Production
Speed Drive Output
Feet per Minute (m/min)
160
(49.1)
Motors
Total
2.0 (1.5)
Main Drive , HP (kW)
1
(0.75)
Discharge Drive , HP (kW)
½
(0.375)
Servo Drive , HP (kW)
1/6
(0.125)
Conveyor Drive 1 , HP (kW)
1/6
(0.125)
Conveyor Drive 2 , HP (kW)
1/6
(0.125)
Electrical
Frequency : All Models 50 / 60 Hz
Total Amps
6.0 5.5 3.0 2.7 2.2
Three Phase Voltage
208 230 380 460 575
Total Amps
17.0
8.5
Single Phase Voltage
115
230
Compressed Air
Maximum Air use , CFM (l/min)
8
½
(238)
Operating Pressure , PSI (kPa)
80-120 (550-820)
Inlet Size , inch
½
Drain Size , inch
¼
Factory recommended settings . Adjust as necessary . Use caution when testing.
Approximate Shipping Weight
Towel Folder
Conveyor
Domestic , lb (kg)
2256 (1023) 350 (160)
Export , lb (kg)
2556 (1160) 500 (225)