6. Press “4” to enter the

Interval Menu. The user will program the

Interval

Time and the Pass Count

in this menu.

The following programming screen will appear:

PASS INTERVAL = 000 MIN
CHANGE TIME = 0 TO 9
ENTER TIME = F KEY
NEW INTERVAL = 045 MIN

7. Enter needed

Interval Time (001 to 255 min.). Press “F” to Save and Exit.

NUMBER OF JOBS 03
ENTER THE PASS COUNT
THEN F KEY TO ENTER
TOTAL PASS COUNT 002

8. Enter the

Pass Count desired for this Auto Zone (000 to 099 passes).

9. Press “F” to Save and Exit to the

Auto Zone Menu. Press “0” to enter

another Auto Zone program (1-E).

ENTER AUTO ZONE NUMB
1 THRU E TIME ZONE #
TO ENTER AUTO MODE
PRESS THE F KEY

10. Press “0” to enter another Auto Zone program (1-E).

11. Once all needed Auto Zones are programmed, press “F” in Auto Zone

Main Menu to enter the

Auto Mode Run

Menu.

TO CHANGE ACTIVE
ZONES 1 3 56 8 ABC E
PRESS KEYS 1 THRU E
0 KEY EXIT, F KEY RUN

***Program all needed Auto Zones before

Pressing “F” to enter the Auto Mode Menu***

12. Enter the number of Auto Zones desired (1 thru E) and press “F” to

RUN

.

Toggle the

ACTIVE AUTO

ZONES

On & Off by

pressing the 1 thru E keys

Summary of Contents for NIC

Page 1: ...1 of 11 Network Irrigation Controller NIC Jobbing w Magnets Version A 28 CHEAT SHEET ...

Page 2: ...eassuring as it can be taught to anyone with very little training The NIC can hold up to 14 different Time Zones each containing a specific start and end time These Time Zones can all be run simultaneously or separately and can be programmed with individual customized time delays Intervals After the time zones are established each one may be programmed with Jobs The NIC is able to store up to 60 J...

Page 3: ...are 4 steps 1 Set up Home Position Home stop 2 Set up Away Position Away stop 3 Set up the number of Jobs to be executed number of Job magnets 4 Give the Boom the Crop watering instructions JOB 3 JOB 1 JOB 1 JOB 2 JOB 3 JOB 2 JOB 02 Magnet JOB 03 Magnet Double Rail Boom tracks rails AWAY Position Magnet End of JOB 03 HOME Position Magnet Start of JOB 01 ...

Page 4: ...mmed must correspond with the Number of Job magnets on the rail If this is not done the JOB COUNT ERROR will appear on the screen and stop the Booms operation until corrected JOB 01 starts at the Home Magnet and end when the Boom sees the first JOB Magnet JOB 02 Magnet JOB 02 starts at the first JOB magnet and ends at the next JOB Magnet et cetera As shown in drawing below Quick Menu Keypad Number...

Page 5: ...01 is needed the cursor must toggle to the next Job DO NOT program that next Job then press E to go to the Pass Count menu If the cursor is not toggled to the next Job screen that last Job programmed will not be saved and will not run This will also result in a JOB COUNT ERROR and stop the operation of the Boom until the problem is fixed To CLEAR the Job press A and follow prompts Press B to GOTO ...

Page 6: ...e Manual Mode main menu _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ M Ma an nu ua al l M Mo od de e R Ru un n J Jo ob bs s Main 2 7 1 From Main menu press 2 for Manual The following screen will appear MANUAL MODE ENTER 1 FOR JOBS ENTER 7 TO BEGIN ENTER E TO EXIT 2 Make sure that the Boom is started BEGIN when the Ho...

Page 7: ...ter 1 E Auto Zone A specific period of time that will activate the Booms operation as programmed Jobs Number of Jobs that the programmed Auto Zone will execute Start Time Time that the Boom will Start this Zones Auto Program execution Stop Time Time that the Boom will Stop this Zones Auto Program execution Interval Amount of minutes between Pass execution Pass Starts at Home goes to Away then turn...

Page 8: ...al Mode Programming section in this manual page 18 4 Press 2 to program a Start Time and then press 3 to program a Stop Time for this Auto Zone Program time in 24 hour format The following programming screen will appear TIME VARIABLE 00 00 ENTER 24 HOUR FORMAT F ENTER NEW TIME NEW TIME VAR 17 43 5 Press F to Save and Exit to the Auto Zone menu Press 2 to Enter the Start Time menu Press 1 to Enter ...

Page 9: ...e 000 to 099 passes 9 Press F to Save and Exit to the Auto Zone Menu Press 0 to enter another Auto Zone program 1 E ENTER AUTO ZONE NUMB 1 THRU E TIME ZONE TO ENTER AUTO MODE PRESS THE F KEY 10 Press 0 to enter another Auto Zone program 1 E 11 Once all needed Auto Zones are programmed press F in Auto Zone Main Menu to enter the Auto Mode Run Menu TO CHANGE ACTIVE ZONES 1 3 56 8 ABC E PRESS KEYS 1 ...

Page 10: ...tion 14 Press E to STOP the Boom and Exit to the Auto Mode menu MODE is displayed here Next AUTO ZONE START TIME is displayed here Current ZONE that the screen is showing is displayed here Active SOLENOIDS are displayed here The Booms SPEED will be displayed here Current programmed TIME displayed here MODE is displayed here DIRECTION OF TRAVEL is displayed here Current PASS ZONE being executed by ...

Page 11: ...nother way of resetting it is by pressing 0 and F simultaneously The NIC will stop the present operation and ask for a four digit code If you press 7638 the NIC will perform a software reset All information will be lost including all setup information If you press 4273 the NIC will perform a hardware reset Again all information will be lost If the wrong code is entered or E is pressed the NIC will...

Reviews: