5 of 11
1. From the Main Menu press 2 for Manual. The following screen will appear:
MANUAL MODE:
ENTER 1 FOR JOBS
ENTER 7 TO BEGIN
ENTER E TO EXIT
2. Press “1” to enter the Jobs Programming screen.
3. The black cursor will scroll thru the screen by pressing “F” to move
forward, and “D” to move back.
Exploded view of the
Manual Mode Programming
Screen:
A)CLR B)GOTO C)+ D)-
JOB01 SPEED VALVES
AWAY 020
1234
HOME 010
5678
4. Program the Job as desired per the user application and press “F” to scroll
to the next Job for programming. If, for example, only JOB #01 is
needed, the cursor must toggle to the next Job (DO NOT program that
next Job), then
press “E” to go to the Pass Count
menu. If the cursor
is not toggled to the next Job screen, that last Job programmed will not
be saved and will not run. This will also result in a “JOB COUNT ERROR”
and stop the operation of the Boom until the problem is fixed.
To
CLEAR
the Job, press
“A” and follow prompts.
Press “B” to
GOTO
another Job number for programming.
Then press “C” to
COPY
this info to other Job numbers.
Enter the
Home
and
Away
speeds
here. 5 to 150 FPM (Feet-Per-Minute)
Enter
Valve Numbers
here by pressing
numbers 1 thru 8. Pressing the number
will toggle that
#
Solenoid ON & OFF.
Press
“C”
to go to the
next Job number.
Press
“D”
to go to the
previous Job number.