18
Warning
•
If the pump is reconstructed arbitrarily or the undesignated parts are used into the pump, Cheonsei
will not warrant and Cheonsei is not responsible for any expense caused by accident or trouble.
14-1 Consumable part
Part Name
Q’ty
Replacement
intervalCheck valve
4
1 year
Diaphragm
2
4,000 hours
O-ring (liquid end)
8
1 year
Oil Seal
3
1 year
Reduction gear
1
1 year
Velocity cam
1
1 year
14-2 Spare Part
•
Spare part(s) for 3 years : bearing / Spare part(s) for 3 years or longer: motor
Warranty period is one year from purchase date.
During warranty period, repair or change of pump is free of charge if trouble or damage of pump due
to design or manufacturing of Cheonsei. (※ Consumable parts are excluded.)
Repair or change product due to following reasons will be charged regardless the warranty period.
①
Trouble or damage of pump expired warranty period.
②
Trouble of using by careless handling.
③
Trouble or damage due to using non-designated part & reconstructing the pump arbitrarily.
④
Trouble by fire or natural disaster
Notes) 1. The each quantity is per a pump.
2. The replacement interval is the
estimate, and it is not guaranteed.
It may vary depending on on-site
condition.
Caution
•
When the pump is sent to factory for repair service, clean out inside of pump.
•
If the pump has been used for harmful & fatal liquid to health, please consult with before sending it.
Contact to Cheonsei or local distributor as shown on back of the manual if you have any problem or questions.
If you want to repair, please inform the following.
①
Model Name & manufacture number written in name plate
②
Used period, using condition, state, and transfer liquid
If warranty period is over, it may charge according to repair part. Please contact with sales agent for more
information.
Minimum retention period of parts for repair is 5 years from the date of production.
14
Consumable Parts and Spare Parts
15
Warranty
16
Repair Service