background image

www.cglifesciences.com 

 

 

[email protected] 

3800 N. Mill Road 

Vineland, NJ 08360 

Phone: 800.843.1794 

Fax: 800.922.4361 

 

ASSEMBLY INSTRUCTIONS FOR 

JACKETED FILTER 

REACTOR SYSTEMS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Support Frame with 

Oversized Rugged S.S. 

Uprights and Heavy-

Duty PTFE Coated 

Aluminum Fittings 

Mechanical Seal 

Stir Bearing 

PTFE Filter Base 

Open Frame 

Design for 

Excellent 

Accessibility 

Heavy Duty 

Lockable Castors 

Detachable Drain 

Valve 

20L Vessel Body 

S.S. Inlet/Outlet 

Adapters Available 

in M16 x 1 and M30 

Summary of Contents for JACKETED FILTER

Page 1: ...IONS FOR JACKETED FILTER REACTOR SYSTEMS Support Frame with Oversized Rugged S S Uprights and Heavy Duty PTFE Coated Aluminum Fittings Mechanical Seal Stir Bearing PTFE Filter Base Open Frame Design f...

Page 2: ...rates in case you need to return items for repair or replacement Crate 1 Unpack the support frame with reactor and components by removing the plastic electrical ties that hold the reactor in place and...

Page 3: ...Klamp II 1ea CG 3498 03 90 Support Rod 1 The support frame has a universal motor mount It can be used with an vertical or horizontal electric air or optional explosion proof XP motor The mount automa...

Page 4: ...embly CG 2095 slides over the end of the shaft The height from the bottom will depend on the total volume you intend to run in the reactor 3 Once you have the upper agitator in place tighten the compr...

Page 5: ...it is pushed down on all edges evenly 5 Wrap the lower outlet adapters with NPT end with PTFE tape Thread the adapter into the filter base until it becomes snug DO NOT OVER TIGHTEN 6 Attach the beade...

Page 6: ...1 glass beaded pipe on the inlet outlet 2 Loosen the nut on the beaded pipe coupling Wet the PTFE Viton liner inside the coupling and attach one side to the 1 beaded pipe on the jacket 3 Insert the b...

Page 7: ...Assemble the stirrer shaft and agitators and lower into the reaction vessel 8 While lowering the reaction vessel lid onto the vessel carefully insert the end of the stirrer shaft through the 45 50 ce...

Page 8: ...www cglifesciences com technical service cglifesciences com...

Page 9: ...www cglifesciences com technical service cglifesciences com Optional Components Safety Shield Side Support Shelf Distillation Side Support Shelf Powder Addition Funnel Data Logger...

Page 10: ...mA or 10 V Zener barriers contain intrinsically safe circuits that are to be used to drive intrinsically safe field devices with hazardous area The manufacturer s data sheets must be consulted The re...