Electric Induction hobs Chef’s EH-xxx330
20
With EH-MIX330:
Fig. 11: Lock / Unclock the TC by press on Key-Lock key in 1 second.
11. Automatic safety off ( induction cooking)
A certain maximum operating time had been fixed for every activated
cooking zone. The maximum operating time depends on the selected cooking
stage. After expiry of the maximum operating time the cooking zone is
switched off automatically providing that no alteration of the settings for that
cooking zone had been made. Any touching of a key assigned to a cooking
zone results in resetting the countdown timer to its starting position.
Cooking stage for RHE:
Cooking Stage
Power [%] Operation time limitation [ Min]
0
0%
0 Min
1
3%
120
2
5%
120
3
8%
120
4
12%
120
5
18%
120
6
28%
90
7
42%
90
8
64%
90
9
100%
90