Electric Induction hobs Chef’s EH-xxx330
10
It is not recommended that the hob be placed between two side walls but,
if this is the case, a gap of at least 200 mm should also be left on one side.
If the induction hob is installed above a sterilizer there must be a gap of
70 mm from the top of worktop to the top of the sterilizer.
If the induction hob is installed without sterilizer or above a drawer, the
worktop thick around the hob must be 20 mm as minimum.
If the interior width of the kitchen unit is less than 700 mm, a 80 mm –
long cut must be made in the side walls from the top section of the hob.
Taking into account the hob ventilation:
An aperture must be cut in the top section of the back of the kitchen unit,
680 mm wide and 45 mm high.
There must be a gap of 20 mm between the back of the kitchen unit and
the kitchen wall.
If the hob is installed above a drawer, allow a gap of 65 mm between the
drawer and the top section of the worktop.
Installing and connecting the hob
The earth wire ( green and yellow) should be connected first and
disconnected last. It should also be longer than the others, so that even if the
hob is moving the other wires can be disconnected before the earth wire.
Connection diagram ( see figure)
1. Brown
2. Blue
3. Green and Yellow
Is required 16A electrical installation at customer’s house (electrical
circuit, socket and fuse ).
Do not trap the lead during installation and do not guide it over sharp
edges.
The hob and the worktop should not be sealed with silicone as the hob
itself has a seal which serves this function.