F10 Installation Manual
Rev. *60
68 of 71
A P P E N D I X
D
DETECTION PERFORMANCE
F10, 2 Meter System
The diagram and corresponding table show the expected FCC and CE detection heights for the
F10, 2 meter system, using a 410EP tag in three different orientations (flat, side, and front carry).
Note: These detection heights are specified for a “clean” environment. If noise is present, detection
performance will be reduced.
Detection Heights
for a 410EP tag with TX = 31 and RX = 31:
A (cm)
B (cm)
C (cm)
D (cm)
E (cm)
F (cm)
Flat
100
120
140
140
120
100
Side
110
125
110
110
125
110
Front
85
100
110
110
100
85
Note: Detection heights are measured from the bottom of the antenna assembly, not from the finished floor
height. F10 system antennas are buried 7.6cm (3”) into the floor.
The following
Detection Patterns
are observed for the F10, 2 meter system. Note that the
orientation of the tag is important as it alters the expected detection height.