CHAPTE R 12
Licensing and Registration
61000 Security Systems have an initial 15-day evaluation license. After the evaluation license
expires, you must license and register the system.
Each chassis is licensed separately. If you have dual chassis system, you must install two licenses.
The license key (CK) is the chassis serial number. The chassis serial number is printed on the
chassis sticker. You can also retrieve the chassis serial number from the CMM.
To retrieve the serial number from the CMM:
1.
Connect to one of the SGMs on the chassis over SSH or console.
2.
Get the IP address of the CMM by running (from
gclish
):
gaia> show chassis id all module CMM1 ip
3.
Using the IP address, open an SSH connection to the CMM:
# ssh <
IP Address of CMM
>
Log in with these credentials:
•
Username:
admin
•
Password:
admin
4.
On the CMM, run:
# clia fruinfo 20 254
5.
The output shows the Chassis Serial Number.
To register the 61000 Security System
1.
https://usercenter.checkpoint.com
2.
In the applicable account, search for the chassis serial number.
3.
Generate a license based on the IP address of the SSM interface connected to your Security
Management Server
.
Note
- Because the 61000 Security System has a single Management IP address, in dual
chassis environments, the Active and Standby chassis should be bound to the same IP address
in the license. Generate two licenses and enter the
same
IP address in each license.
4.
Install the license on the system.
•
If you use the
cplic put
command, run it from
gclish
, so that it applies to all SGMs.
•
Run the
cplic put
command twice, if you have a dual chassis environment.