background image

- 3 -

3.0 O

VERVIEW

Metal Enclosure

Flash Tube

Reflector

Screw-Off Plastic Lens

On Back: Sockets for trigger input
and supply voltage, ON/OFF Switch,
LED Power Indicator 

Plug for trigger input and
power supply

On Bottom: 3 threaded holes for 
equipment mounting, tripod connection 

Optional Accessories

•  Spare flash tube
• Tripod / wall mounting bracket
•  Power supply unit
•  Additional plug for trigger 

input / power supply

• Connecting cable with plug 

connector to the LS-5-12000 
and open cable connection 
for external equipment

•  LS-5-RCU Control Unit 

(not shown)

- 6 -

5.0 O

PERATION

1.  Position the stationary

stroboscope and connect the
trigger input signal and supply 
voltage to the sockets as outlined 
in Section 4.0

2.  Switch the stroboscope on. The 

red LED will light, indicating that 
the unit is ready for use.

2 . As soon as the trigger signal is 

applied, the strobe will start to 
flash with the trigger frequency.

3.  If the flashing frequency coincides with the movement frequency,

a stationary image will appear.

NOTE:

A stationary image will not only appear with an identical 
flashing frequency, but also with multiples and fractions of 
the flashing frequency.

Summary of Contents for LS-5-12000

Page 1: ...igger Input 3 to 30 V max 5 mA potential free optocoupler DIN 41524 5pin standard connector Uout 24 V max 200 mA Housing Material Aluminum Size 6 0 x 5 1 x 4 4 150 x 130 x 112mm Weight 870 g Ambient Temp 32 to 104 F 0 to 40 C Storage Temp 13 to 158 F 25 to 70 C Humidity Max 95 not condensed Flash Tube Parameters Lifetime 200 000 000 flashes 6 000 FPM Flash Duration 5 µs Light Emission Flash 10 Meg...

Page 2: ...rge before replacing the flash tube Any service beyond flash tube replacement is not recommended Do not look directly at the emitted light it can damage your eyes It may also trigger seizures in people with photosensitive epilepsy Flash tubes are filled with high pressure gas When handling the flash tube always always wear safety glasses and protective gloves Do not allow inflammable liquids and w...

Page 3: ...open cable connection for external equipment LS 5 RCU Control Unit not shown 6 5 0 OPERATION 1 Position the stationary stroboscope and connect the trigger input signal and supply voltage to the sockets as outlined in Section 4 0 2 Switch the stroboscope on The red LED will light indicating that the unit is ready for use 2 As soon as the trigger signal is applied the strobe will start to flash with...

Page 4: ...connect the trigger signal CAUTION Do not trigger the stroboscope with signals above 12 500 FPM 4 1 Typical connection examples Please take connection examples from Figures 2 to 5 Note that you will need optional accessories for some of the examples stationary strobo scope AC Adapter sensor etc Fig 2 Trigger signal and supply voltage from external equipment Fig 1 Fig 2 5 Fig 3 Trigger signal from ...

Page 5: ... RESULTING FROM THE USE OF SUPPLIED EQUIPMENT WHETHER SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE UPON OR AFTER REPLACEMENT OR REPAIR AND WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFACTURER S OR SUPPLIER S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE Some State jurisdictions or States do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not ap...

Page 6: ...TIC E Q U I P M E N T C O I N C 600 Oakland Ave Cedarhurst NY 11516 U S A TEL 516 295 4300 FAX 516 295 4399 CHECK LINE INSTRUMENTS LS 5 12000 LINEAR STROBOSCOPE Operating Instructions CHECK LINE BY ELECTROMATIC ...