ADJUSTMENT INFORMATION
5
Adjusting the planting unit load
The adjustment unit is usually mounted in position
(
A1
).
With the unit (
A
) in position (
A1
) the weight on the pack-
ing wheels can be reduced.
With the unit (
A
) in position (
A2
) the weight on the pack-
ing wheels can be increased.
The weight (load) to be applied to the packing wheels
is obtained by the combined action of the adjustment
units (
A
) and (
B
).
To adjust the transplanting unit load proceed as outlined
below.
1) As regards the position of the adjustment unit (
A
),
turn the handwheel (
C
) and the handwheel (
D
) to ap-
ply the ideal weight to the packing wheels.
Adjusting the automatic safety release function
The automatic release is designed to protect the trans-
mission components from overloads (e.g. if the dispens-
er or ejector jams).
The device, installed on every planting unit, is already set
by the manufacturer during the testing stage, but can be
adjusted by the user according to requirements.
For adjustments, proceed as outlined below.
1) Turn the ring nut (
A
) clockwise to increase the release
resistance (i.e. less sensitive).
2) Turn the ring nut (
A
) anticlockwise to decrease the
release resistance (i.e. more sensitive).