                                                                                                                                          Operation Requirements 

 

 

 

ALPHAAIR 450 USER MANUAL

 

| 2021-03

 

 

P a g e  |  5

 

2 Operation Requirements 

2.1 

Operation Environment

 

 

It is not recommended to use in rainy, snowy, or foggy weather for safety. Also, the point 
cloud data will have more noise.

 

 

It  is  not  recommended  to  frequently  use  in  dusty  environment,  which  will  affect  the 
service life of equipment.

 

 

It  is  forbidden  to  expose  the  device  and  accessories  under  extreme  temperature.  The 
environment  temperature  must  not  be  lower  or  higher  than  the  specification 
temperature.

 

 

When the equipment  is  transferred  from a cold environment  to a warm environment, 
water  may  condense  on  certain  components  inside  the  scanner.  To  avoid  this,  it  is 
recommended to place the scanner in a sealed plastic bag before transferring. When the 
condensate is evaporated, then turn on the plastic bag.

 

 

2.2 

Attentions before Using

 

 

Check whether the laser glass is normal, if there is dust exist, please use the cleaning kit 
to clean it.

 

 

Check whether the ports are clean, and whether the pins are normal.

 

 

Check whether the connecting cables are reliable and stable, and whether the GPS cable 
is stable and normal.

 

 

Check whether the remote controller has sufficient power. 

 

 

2.3 

Attentions when Using

 

 

Please  ensure  all cables are  connected to correct  ports based on one-by-one  check to 
avoid mistake. Do not insert or extract cables forcibly.

 

 

After  powered  on,  check  whether  the  connection  between  remote  controller  and 
equipment is normal, and whether the status of tracking satellite and board is normal 
(the  "A"  icon  in  the  CHCHAV  logo  on  the  upper  left  side  of  the  controller  will  display 
orange  which  indicate  the  connection  is  normal,  otherwise,  the  communication  is 
abnormal if always show gray).

 

 

The  instrument  should  put  at  an  open  &  good  signal  place  when  start  work.  Check 
whether GPS satellites’ signal is normal.

 

 

If buzzer is not ringing properly after startup or during data capture process, please check 
whether instrument is normal immediately.

 

 

Check the rest volume of SSD drive before data capture start. If rest volume less than 10% 
or not enough for this time’s requirement, please delete laser data files in advance.

 

 

Before  start  work,  please  check  whether  the  controller’s  laser  parameter  settings  are 

Summary of Contents for AlphaAir 450

Page 1: ...Make your work more efficient CHCNAV AlphaAir 450 User Manual Mobile Mapping March 2021...

Page 2: ...troduction 7 3 2 Configuration List 7 3 3 Product Introduction 8 3 4 Product Dimensions 8 3 5 Electrical Characteristics 9 3 6 Airborne Platform 9 3 6 1 Airborne installation steps using Skyport 9 3 6...

Page 3: ...could result in death or serious injury WARNING Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor or moderate injury NOTICE Indicates a potentia...

Page 4: ...dard prices The customer should provide a stable vehicle roof rack in accordance with the requirements of the technical indicators If the equipment is broken or damaged due to 3rd brand s reason CHCNA...

Page 5: ...are normal Check whether the connecting cables are reliable and stable and whether the GPS cable is stable and normal Check whether the remote controller has sufficient power 2 3 Attentions when Using...

Page 6: ...e read this manual carefully before starting the system All users must follow the safety directions given by the manufacturer and the directions of the person responsible for the product The person re...

Page 7: ...rue color point cloud and other results can be generated and road sections power lines vegetation and other results can be automatically extracted for analysis and the inspection report can be output...

Page 8: ...System Overview ALPHAAIR 450 USER MANUAL 2021 03 P a g e 8 3 3 Product Introduction The product diagrams are shown below 3 4 Product Dimensions Weight 1 0 kg Length width and height are shown below...

Page 9: ...perature 20 C to 50 C Storage temperature 20 C to 65 C Humidity 80 non condensation 3 6 Airborne Platform 3 6 1 Airborne installation steps using Skyport Press the Skyport unlock button to remove the...

Page 10: ...the other end of the GNSS feeder to the GNSS interface of the AA450 3 6 2 Airborne disassemble steps using Skyport Take out the GNSS feeder from the AA450 GNSS interface rotate the GNSS antenna count...

Page 11: ...o check the remaining capacity of Alpha_LAS and Alpha_CAM memory cards If the remaining capacity is less than 10 or does not meet the demand of current collection capacity the data in card should be d...

Page 12: ...ered on successfully Device initialization about two minutes after lidar is powered on the indicator light is normal on which means device initialization successfully completed Start project after suc...

Page 13: ...LiDAR Turn Off ALPHAAIR 450 USER MANUAL 2021 03 P a g e 13 6 LiDAR Turn Off Before turning off equipment please make sure the project is already stopped Long press the ON OFF key to turn off equipment...

Page 14: ...LPHA_LAS the folder is named by the date of collection xxxxxx_I imr IMU data xxxxxx_S TXT synchronizes data xxxxxx_T gps GNSS data xxxxxx_L lv laser data Open ALPHA_CAM the images are stored in DCIM f...

Page 15: ...the project file according to the POS time multiple groups of data can be copied at the same time Click the data into icon and the selected data name will be moved to the right bar Then click copy and...

Page 16: ...ation Generally we need Rinex format If base data is other formats please convert it into Rinex format first For example HCN file ROVER This folder contains GNSS data and IMU data which recorded by Al...

Page 17: ...If still can t power on or power off please contact CHCNAV Support team for repair Equipment can t be timed or need long time Check whether the GPS feeder cable connection is stable Alpha_LAS memory...

Page 18: ...without cutting off the power supply Do not continue using any broken cables Please purchase and replace new cables in time to avoid unnecessary damage Avoid any strong impact or vibration Use an umbr...

Page 19: ...s disassembled or loosen it should be re calibrated When it is difficult to rotate any rotating parts of the equipment please do not forcibly rotate After the equipment is damaged please do not contin...

Page 20: ...R MANUAL 2021 03 P a g e 20 CHC Navigation Building D NO 599 Gaojing Road Qingpu District 201702 Shanghai China Tel 86 21 542 60 273 Fax 86 21 649 50 963 Email sales chcnav com support chcnav com Skyp...

Reviews: