background image

Vue™ 1.1 User Manual 

Rev. 4 

Hanging Clamp 

Note! 
Clamp is sold separately. 

3.

 

S

ETUP

 

 

Fuse Replacement 

With a flat-head screwdriver, unscrew the fuse holder from its housing. Remove the damaged fuse from its 
holder and replace with exact same type fuse. Screw the fuse holder back in its place and reconnect 
power.  

Disconnect the power cord before replacing a fuse and always replace with the same type fuse. 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run 
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number 
of channels required by all the fixtures on a serial data link determines the number of fixtures the data link 
can support. Details on linking for DMX can be foundinthe DMX Primer, available from 

www.chauvetlighting.com

.  

Important:  

Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-485 

standard no more than 32 fixtures should be connected on one data link. Connecting more than 32 

fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in 

deterioration of the digital DMX signal.  

Maximum recommended serial data link distance: 500 m (1640 ft) 

Maximum recommended number of fixtures on a serial data link: 32 

DMX Data Cable 

Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. 
Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will have 
the following characteristics: 

2-conductor twisted pair plus a shield 
Maximum capacitance between conductors – 30 pF/ft. 
Maximum capacitance between conductor and shield – 55 pF/ft. 
Maximum resistance of 20 ohms / 1000 ft. 
Nominal impedance 100 – 140 ohms 

Master/Slave Fixture Linking 

1.  Connect the (male) 3-pin connector side of the DMX cable to the output (female) 3-pin connector of the 

first fixture.   

2.  Connect the end of the cable coming from the first fixture which will have a (female) 3-pin connector to 

the input connector of the next fixture consisting of a (male) 3-pin connector. Then, proceed to connect 
from the output as stated above to the input of the following fixture and so on. 

Mounting 

Orientation 

This fixture may be mounted in any safe position, provided there is adequate room for ventilation. 

Rigging  

It is important never to obstruct the fan or vents pathway. Mount the 
fixture using, a suitable C or O type clamp. Adjust the angle of the fixture 
by loosening both knobs and tilting the fixture. After finding the desired 
position, retighten both knobs. 

When selecting installation location, take into consideration lamp 
replacement access and routine maintenance.  

Safety cables must always be used.  

Never mount in places where the fixture will be exposed to rain, high humidity, extreme 
temperature changes or restricted ventilation. 

 

Summary of Contents for Vne 1.1

Page 1: ... Sunrise FL 33351 U S A 800 762 1084 954 577 4455 FAX 954 929 5560 www chauvetlighting com User Manual Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master Slave 120 230 V switch Replaceable Fuse User Serviceable ...

Page 2: ... 5 FUSE REPLACEMENT 6 FIXTURE LINKING 6 DMX Data Cable 6 MASTER SLAVE FIXTURE LINKING 6 MOUNTING 6 Orientation 6 Rigging 6 4 Operating Instructions 7 STANDALONE MODE SOUND ACTIVE AUTO MODE 7 DMX MODE 7 DMX Channel Values 7 Setting the Starting Address 8 DMX QUICK REFERENCE CHART 9 DMX Address Quick Reference Chart 9 GENERAL TROUBLESHOOTING 10 5 Appendix 11 GENERAL MAINTENANCE 11 RETURNS 11 CLAIMS ...

Page 3: ...ected to circuits with a suitable Earth Ground Safety Instructions Please keep this User Manual for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture Thi...

Page 4: ... LEDs Built in automated programs via master slave or DMX Built in sound activated programs via master slave or DMX ADDITIONAL FEATURES Linkable with Vue 1 1 Vue 2 1 and Vue 6 1 Adjustable hanging bracket with slide rail DMX Channel Summary CHANNEL FUNCTION 1 Control Operating Mode 2 Red 3 Green 4 Blue 5 Strobing Speed Stand alone Speed 6 Dimmer ...

Page 5: ...Vue 1 1 User Manual 5 Rev 4 Product Overview DMX output Hanging Bracket Fuse holder Sound sensitivity Bracket Adjustment knob Dipswitches Front Lens DMX input Voltage selection switch ...

Page 6: ...le Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable will have the following characteristics 2 conductor twisted pair plus a shield Maximum capacitance between conductors 30 pF ft Maximum capacitance between conductor and shield 55 pF ft Maximum resistance of 20...

Page 7: ... recognize master slave operation when connected properly The first fixture will be set as the master and all fixtures following this will set as slave fixtures You must follow daisy chain configuration for this type of setup Note Do not connect a DMX controller to the fixture s when you are trying to run them standalone as this will put them in DMX mode automatically DMX Mode This mode allows the...

Page 8: ... start address Turn this switch on 2 Subtract the value of the switch you just turned on from the starting address number 3 Determine the largest value switch that is less than the remainder from the previous subtraction Turn this switch on 4 Subtract the value of the switch you just turned on from the remainder of the previous subtraction 5 Repeat steps three and four until you have a remainder o...

Page 9: ...428 460 492 1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493 0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494 1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495 0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496 1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497 0 1 0 0 1 18 50 82 114 146 178 21...

Page 10: ...eck for power on Mains Check device s fuse internal and or external ü ü ü Fixture is not responding Check DMX Dip switch settings for correct addressing Check DMX cables Check polarity switch settings ü Fixture is on but there is no movement to the audio Make sure you have the correct audio mode on the control switches If audio provided via jack make sure a live audio signal exists Adjust sound se...

Page 11: ...dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Returns Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call CHAUVET and request RMA prior to shipping t...

Page 12: ...rature 104 F 40 C CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols USITT DMX512 A DMX Channels 6 ORDERING INFORMATION Vue 1 1 VUE1 1 WARRANTY INFORMATION Warranty 2 year limited warranty Contact Us Worldwide General Information CHAUVET Lighting 5200 NW 108th Avenue Sunrise FL 33351 voi...