General Maintenance 

To maintain optimum performance and minimize wear fixtures should be cleaned frequently.  Usage 

and environment are contributing factors in determining frequency. As a general rule, fixtures should 

be cleaned at least twice a month. Dust build up reduces light output performance and can cause 

overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off 

fixture before conducting maintenance. 

Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust 

collected on external vents and internal components.  Clean all glass when the fixture is cold with a 

mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply 

solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical 

surfaces until they are free of haze and lint.  

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: 

damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s 

optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean 

the external optics at least every 20 days. Clean the internal optics at least every 30/60 days. 

Returns Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 

Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products 

returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the 

fixture. Be prepared to provide the model number, serial number and a brief description of the cause 

for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate 

packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to 

repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe 

method to use. 

Note: 

If you are given an RA #, please include the following information on a piece of paper 

inside the box: 

1) Your 

name 

2) Your 

address 

3) Your 

phone 

number 

4) 

The RA # 

5) 

A brief description of the symptoms 

SX Abyss Manual 

9

2006-12-11/15:07

Summary of Contents for SX Abyss

Page 1: ...utdoor OK Sound Activated DMX512 Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com ...

Page 2: ...2 INTRODUCTION 5 FEATURES 5 PRODUCT OVERVIEW 5 3 SETUP 6 LAMP 6 Lamp Installation 6 Fuse Replacement 7 MOUNTING 7 Orientation 7 Rigging 7 4 OPERATING INSTRUCTIONS 7 GENERAL TROUBLESHOOTING 8 TECHNICAL SUPPORT 9 5 APPENDIX 9 GENERAL MAINTENANCE 9 RETURNS PROCEDURE 9 CLAIMS 10 TECHNICAL SPECIFICATIONS 10 SX Abyss User Manual 2 2006 12 11 15 07 ...

Page 3: ...tures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture check that the source voltage matches the fixture s requirement Check the fixture or device carefully to make sure that if a voltage selection switch exists that it i...

Page 4: ...fuse and be sure to replace with same lamp source x Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its carrying handles x Maximum ambient temperature Ta is 95 F 35 C Do not operate fixture at temperatures higher than this x In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Rep...

Page 5: ...hanging dichroic colors x Stop effect on a color x Adjustable ripple speed x Fan cooled Product Overview Power Cord Fuse Focusing Lens Color Rotation Switch Effect Speed Knob Lamp Access Thumbscrew Hanging Bracket Lamp Access Thumbscrew SX Abyss User Manual 5 2006 12 11 15 07 ...

Page 6: ...he lamp with alcohol and wipe it with a lint free cloth before installation Lamp Installation Figure A Figure B Figure C 1 Unscrew the two thumbscrews Figure A 2 Hold the lamp removal knob and pull the lamp housing directly out Figure B 3 Slide the lamp up past the spring clips to remove it Figure 3 4 Remove the lamp from the socket Figure C 5 Hold the new lamp with a lint free c Insert lamp into ...

Page 7: ...clamp Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs x When selecting installation location take into consideration lamp replacement access and routine maintenance x Safety cables should always be used Note Clamp is sold separatel x Never mount in places where the fixture will be exposed to rain high humidity ...

Page 8: ...nd of its life 9 Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up 9 Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights 9 9 9 9 Moves slow Check 220 110v switch for proper setting 9 No fl...

Page 9: ...s and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean th...

Page 10: ...ipping and concealed damage must be made within seven 7 days of receiving merchandise Technical Specifications WEIGHT DIMENSIONS Length 13 in 330 mm Width 12 5 in 318 mm Height 7 in 178 mm Weight 8 7 lbs 4 kg POWER Switch selectable power settings 120V 60Hz AC or 230V 50Hz Fuse 6 3A 250V Power Consumption 276W Max Inrush Power 348W LIGHT SOURCE Lamp ELC3 24V 250W Lamp PHOTO OPTIC Beam Angle 44 THE...