Setup
-6-
Rogue R2X Spot User Manual Rev. 2
3.
S
ETUP
AC Power
Each Rogue R2X Spot has an auto-ranging power supply that works with an input voltage range
of 100 to 240 VAC, 50/60 Hz. To determine the power requirements for each Rogue R2X Spot,
refer to the label affixed to the product. You can also refer to the
in this manual.
The listed current rating indicates the maximum current draw during normal operation. For more
information, you may download Sizing Circuit Breakers from the Chauvet website:
www.chauvetlighting.com/download/pro
•
Always connect this product to a protected circuit with an appropriate electrical
ground to avoid the risk of electrocution or fire.
•
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.
AC Plug
The Rogue R2X Spot comes with a power input cord terminated with a Neutrik powerCON A
connector on one end and an Edison plug on the other end (U.S. market). If the power input
cord that came with your product has no plug, or if you need to change the Edison plug, use the
table below to wire the new plug.
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
Fuse
Replacement
1. Disconnect this product from the power outlet.
2. Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove the blown fuse and replace with another fuse of the same type and rating
(F 7 A, 250 V).
4. Screw the fuse holder cap back in place and reconnect power.
Make sure to disconnect the product’s power cord before replacing a blown fuse. Always
replace the blown fuse with another of the same type and rating.
Power Linking
The Rogue R2X Spot supports power linking. You can power link up to 3 products at 120 V; up
to 6 at 208 V; or up to 7 at 230 V.
This product comes with a power input cord. Power linking cables are available from Chauvet
for purchase.
DMX Linking
You can link the Rogue R2X Spot to a DMX controller using a 3- or 5-pin DMX connection. If
using other DMX-compatible products with the Rogue R2X Spot, you can control each
individually with a single DMX controller.