5.

 

T

ECHNICAL 

I

NFORMATION

 

 

General Troubleshooting 

 

Symptom Possible 

Cause(s) 

Possible 

Action(s) 

General low light intensity 

Dirty LEDs 

Clean the MotionDrape™ LED drape regularly  

One LED in an LED group 
failed 

Faulty (shorted) LED 

Replace faulty LED  

All the LEDs in a group 
failed 

Faulty (open) LED 

Replace faulty LED 

Faulty LED cable 

Replace faulty LED cable 

Faulty LED driver 

Replace faulty LED Driver box  

Single MotionDrape™ LED 
controller: All LEDs in a 
drape failed 

Faulty LED driver box 

Replace faulty LED Driver box 

Faulty drape output cable  

Repair or replace faulty cable 

Faulty MotionDrape™ LED controller 

Replace MotionDrape™ LED controller 

Multiple MotionDrape™ LED 
controllers: All LEDs on a 
controller failed 

Faulty MotionDrape™ LED controller 

Replace MotionDrape™ LED controller 

If using DMX connection, wrong DMX address 
on the corresponding controller 

Set the starting DMX address correctly 

If using proprietary serial link, wrong 
Master/Slave setting on the corresponding 
controller 

Set the starting Master/slave mode correctly 

MotionDrape™ LED controller not powered 

Check power to the MotionDrape™ LED 
controller 

Faulty DMX cable 

Repair or replace faulty cable 

Breaker/Fuse keeps blowing 

Excessive circuit load 

Check total load placed on the electrical circuit 

Short circuit along the power wires 

Check for a short in the electrical wiring (internal 
and/or external) 

MotionDrape™ LED 
controller does not power 
up 

No power 

Check for power on Mains 

Faulty or lose power cord 

Check power cord 

Faulty internal power supply 

Replace internal power supply 

Product is not responding to 
DMX 

Wrong DMX addressing 

Check DMX controller and product addressing 

Wrong polarity on the controller 

Check polarity switch settings on the controller 

Lose or damaged cables 

Check DMX and signal patch cables 

Faulty Main PCB 

Replace Display PCB 

Loss of signal on some 
MotionDrape™ LED 
controllers 

Non compatible signal patch cables 

Use only compatible cables 

Bouncing signals 

Install terminator as suggested 

Long cable / Low level signal 

Do not exceed maximum recommended length 

Too many products 

Install an optically coupled DMX splitter after unit 
#32. 

Interference from AC wires 

Keep DMX and signal patch cables separated 
from power cables or black lights 

 

 

If you still experience problems after trying the above solutions, contact 
CHAUVET® Technical Support. 

 

 

 

 

Summary of Contents for MotionDrape LED

Page 1: ...User Manual ...

Page 2: ...lacement 7 Mounting 8 Orientation 8 Rigging 8 4 Operation 9 Control Panel Operation 9 Menu Map 9 Configuration DMX 9 Starting Address 9 Configuration Standalone 10 Sound Active Mode 10 Automatic Mode 10 DMX Channel Assignments and Values 11 8 CH 11 5 Technical Information 12 General Troubleshooting 12 Contact Procedure 13 CHAUVET Contact Information 13 Returning Products to CHAUVET 13 DMX Primer 1...

Page 3: ...s of which only one can be chosen Settings A menu option not to be modified Menu Settings A sequence of menu options to be followed ENTER A key to be pressed on the product s control panel ON A value to be entered or selected Icons Icon Meaning This paragraph contains critical installation configuration or operation information Failure to comply with this information may render the product partial...

Page 4: ...at the voltage of the outlet to which you are connecting this product is within the range stated on the decal or rear panel of the product This product is for indoor use only IP20 To prevent risk of fire or shock do not expose this product to rain or moisture Always install this product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation ...

Page 5: ...MotionDrape LED User Manual Rev 03 Page 5 of 16 2 INTRODUCTION Product Overview LED Display Button Menu On Off Switch Fuse holder Front Panel DMX In DMX Out Curtain Input Power In Top Panel ...

Page 6: ...Page 6 of 16 MotionDrape LED User Manual Rev 03 Product Dimensions ...

Page 7: ...to avoid the risk of electrocution or fire Never connect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement Follow the instructions below to change the fuse if necessary Disconnect this product from the power outlet before replacing the fuse 1 Wedge the tip of a flat head screwdriver into the slot ...

Page 8: ...y to access the unit for maintenance and programming purposes Make sure that the structure onto which you are mounting this product can support its weight Please see the Technical Specifications section of this manual for weight information Mount the product securely to a rigging point whether an elevated platform or a truss Reusable zip ties tie wraps are provided with the MotionDrape LED for qui...

Page 9: ... program runs Program 1 30 NO Disables numbered program running in sequence in auto or sound mode YES Enables numbered program running in sequence in auto or sound mode Configuration DMX Set this product in DMX mode to control it with a DMX controller 1 Connect this product to a suitable power outlet 2 Turn this product on 3 Connect a DMX cable from the DMX output of the DMX controller to the DMX ...

Page 10: ... mode may transmit DMX signals that could interfere with the DMX signals from the controller Sound Active Mode To enable the Sound Active mode do the following 1 Press MENU repeatedly until Sound shows on the display 2 Press ENTER 3 Use UP or DOWN to select Yes 4 Press ENTER 5 Turn the music on until the product responds to the beat of the music The product will only respond to low frequencies of ...

Page 11: ...tack 096 111 Multi Color Freeway 112 127 Color Wave L R 128 143 Color Wave R L 144 159 Color Bar Chase L R 160 175 Color Bar Chase R L 176 191 Windmill 192 207 Fan 208 223 Whirlpool 224 239 Falling Snow 240 255 Multi Box Frenzy 7 Programs 16 30 000 015 No function 016 031 Center Burst 032 047 Outer Burst 048 063 EQ Effect 064 079 Rolling Color 080 095 Horizontal Stacking 096 111 Inner Zone 112 127...

Page 12: ...LED controller not powered Check power to the MotionDrape LED controller Faulty DMX cable Repair or replace faulty cable Breaker Fuse keeps blowing Excessive circuit load Check total load placed on the electrical circuit Short circuit along the power wires Check for a short in the electrical wiring internal and or external MotionDrape LED controller does not power up No power Check for power on Ma...

Page 13: ...e the US United Kingdom or Ireland contact your distributor of record and follow their instructions on how to return CHAUVET products to them Visit our Web site for contact details Returning Products to CHAUVET Call the corresponding CHAUVET Tech Support office and request a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial numbe...

Page 14: ...ll control product A This means that the user should assign the starting address of product B to 005 or higher For a starting address of 005 the DMX controller would use channels 005 to 010 to control product B It is possible to control multiple products of the same type by assigning each one of them the same starting address In this case all the products would respond in unison synchronized to th...

Page 15: ...ctor on the other end The DMX protocol indicates that the XLR connectors must have five pins However most lighting products use the 3 pin XLR connector The pin assignment of the 3 pin and 5 pin XLR connectors in a DMX cable is as follows Male Plug Female Plug Signal 3 Pin 5 Pin 5 Pin 3 Pin Signal Common 1 1 1 1 Common Data 2 2 2 2 Data Data 3 3 3 3 Data Not used 4 4 Not used Not used 5 5 Not used ...

Page 16: ...l digit Power Power Supply Type Range Voltage Selection Switching internal 100 240 V 50 60 Hz Auto ranging Parameter 120 V 60 Hz 230 V 50 Hz Consumption 51 W 54 W Operating 0 4 A 0 2 A Fuse F 2 A 250 V F 2 A 250 V Power I O US Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison US Local plug Light Source Type Quantity Lifespan LED 176 50 000 h...

Reviews: