7
Once the address has been selected, press the
ENTER
button to setup or automatically return
to the main functions without any change after 8 seconds. To go back to the functions without
any change press the
MENU
button again.
.
Show Mode
Press the
MENU
button up To when the
is shown on the display. Pressing
ENTER
button and the display will blink. Use
DOWN
and
UP
button to select the
(show 1) or
(show 2) mode. Once the mode has been selected, press the
ENTER
button to setup
or automatically return to the main functions without any change after 8 seconds. To go back to
the functions without any change press the
MENU
button again.
Show 1 mode- Fixture is placed on the floor. Tilt movement angle 210°.
Show 2 mode-Fixture is fixed under ceiling. Tilt movement angle 90°.
Slave Mode
Press the
MENU
button up to when the
is shown on the display. Pressing
ENTER
button and the
display will blink. Use
DOWN
and
UP
button to select the
(normal) or
(2 light show) mode. Once the mode has been selected, press the
ENTER
button to
setup or automatically return to the main functions without any change after 8 seconds. To go
back to the functions without any change press the
MENU
button again.
Pan Inversion
Press the
MENU
button up to when the
is shown on the display. Pressing
ENTER
button and the display will blink. Use
DOWN
and
UP
button to select the
(normal) or
(pan inversion) mode. Once the mode has been selected, press the
ENTER
button to
setup or automatically return to the main functions without any change after 8 seconds. To go
back to the functions without any change press the
MENU
button again.
Tilt Inversion
Press the
MENU
button up to when the
is shown on the display. Pressing
ENTER
button and the display will blink. Use
DOWN
and
UP
button to select the
(normal) or
(pan inversion) mode. Once the mode has been selected, press the
ENTER
button to setup or
automatically return to the main functions without any change after 8 seconds. To go back to the functions
without any change press the
MENU
button again.
.
Display Inversion
It is good for you to install the unit on the floor or under ceiling. Press the
MENU
button up
to when the
is blinking on the display. Use the
ENTER
button to change to the mode
(display inversion), It will automatically store after 8 seconds. Or press the
ENTER
button again return to the mode
(display normal). To go back to the functions press the
MENU
button.
Display normal mode for the fixture putting on the floor.
Display inversion mode for the fixture fixing under ceiling.
Focus Adjust
Press the
MENU
button up to when the
is blinking on the display. Pressing
ENTER
button, the unit will focus on tilt 90°, and then the unit will focus on pan 0°, pan 90°, pan180°,
pan270° in every pressing
ENTER
button. To go back to the functions press the
MENU
button
again.
Self-Test
Press the
MENU
button up to when the
is blinking on the display. Pressing
ENTER
button and the unit will run self-test by built in program. To go back to the functions press the
MENU
button again.
Fixture Hours
Press the
MENU
button up to when the
is blinking on the display. Pressing
ENTER
button and the display will show the number of working hours of the unit. To go back to the
functions press the
MENU
button again.
Reset
Press the
MENU
button up to when the
is blinking on the display. Pressing
ENTER
button and all channels of the unit will return to their standard position. To go back to the
functions press the
MENU
button again.