background image

 

5. Appendix 

1/11/2011 6:12 PM  

 

5.

 

A

PPENDIX

 

 

 

General Troubleshooting 

 

 

 

S

YMPTOM

 

P

OSSIBLE 

C

AUSE

(

S

P

OSSIBLE 

A

CTION

(

S

Breaker/Fuse 

keeps blowing 

  Excessive circuit load 

  Check total load placed on the 

electrical circuit. 

  Short circuit along the power 

wires 

  Check for a short in the electrical 

wiring (internal and/or external). 

Device does not 

power up 

  No power 

  Check for power on Mains. 

  Loose power cord 

  Check power cord 

  Blown fuse 

  Replace fuse with same type & 

rating 

 

 

 

 

If you still have a problem after trying the above solutions, please contact CHAUVET® 
Technical Support. 

 

 

 

 

Summary of Contents for LX-15

Page 1: ...LX 15 User Manual ...

Page 2: ...ne Revision 01a Release Date 12 27 2010 TABLE OF CONTENTS 1 BEFORE YOU BEGIN 3 WHAT IS INCLUDED 3 UNPACKING INSTRUCTIONS 3 MANUAL CONVENTIONS 3 ICONS 3 SAFETY INSTRUCTIONS 4 2 INTRODUCTION 5 PRODUCT OVERVIEW 5 3 SETUP 6 AC POWER 6 MOUNTING 7 Orientation 7 Rigging 7 4 OPERATING INSTRUCTIONS 8 Standalone Sound Active 8 5 APPENDIX 9 GENERAL TROUBLESHOOTING 9 GENERAL MAINTENANCE 10 RETURNS PROCEDURE 1...

Page 3: ...lar text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons This manua...

Page 4: ...ct from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by un...

Page 5: ...2 Introduction 5 1 11 2011 6 12 PM 2 INTRODUCTION Product Overview Safety Fuse holder Power In Microphone Microphone Sensitivity Back Panel ...

Page 6: ...ture see the label affixed to the back plate of the fixture or refer to the fixture s specifications chart A fixture s listed current rating indicates its average current draw under normal conditions Always connect the fixture to a switched circuit Never connect the fixture to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used only as a 0 to 100 switch Al...

Page 7: ...securely This may be done with a screw nut and bolt or a hanging clamp The hole in each bracket is 13 mm in size When rigging consider routine maintenance and access Please see the following notes on installation When aiming the fixtures you may use the bracket adjustment knob Loosen the knob adjust to the desired angle and then tighten the knob by turning clockwise Do not use tools for this step ...

Page 8: ...IONS Standalone Sound Active Please see the instructions below for details on this mode 1 Plug the fixture into power 2 Rotate the microphone sensitivity adjustment knob until the desired level has been reached The microphone will only respond to low frequencies bass ...

Page 9: ...placed on the electrical circuit Short circuit along the power wires Check for a short in the electrical wiring internal and or external Device does not power up No power Check for power on Mains Loose power cord Check power cord Blown fuse Replace fuse with same type rating If you still have a problem after trying the above solutions please contact CHAUVET Technical Support ...

Page 10: ...king call tags will not be issued Package must be clearly labeled with a Return Merchandize Authorization Number RMA Products returned without the RMA will be refused Call CHAUVET and request an RMA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to pack fixture properly any shipping damage resulting fr...

Page 11: ...ption 120 V 12 W 0 1 A max Power consumption 230 V 11 W 0 1 A max Fuse F 1 A 250 V LIGHT SOURCE Type high power tri color single source LED Quantity 1 Rating RGB 3 W 350 mA x 3 50 000 hrs PHOTO OPTIC Coverage angle 36 INDOOR OUTDOOR Rating For indoor use only THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION LX 15 LX15 WARRANTY INFORMATION Warranty 1 year limited warranty ...

Page 12: ...54 929 1115 Press 4 Fax 954 929 5560 Attention Service Email tech chauvetlighting com World Wide Web http www chauvetlighting com UNITED KINGDOM IRELAND General Information CHAUVET Europe Ltd Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 EMail uktech chauvetlighting com World Wide Web http www chauvetlighting co uk ...

Reviews: