background image

Cleaning

The most important part of your lighting effect to keep clean are the mirrors as they allow the light output to transmit. They
should be cleaned with a soft damp cloth. There is also a single mirror located under the center cap that should also be
cleaned. The body of the unit may also be cleaned in the same way. We recommend internal cleaning be carried out by a fully
qualified technician.

Maintenance & Servicing

Work on internal parts should be carried out by a qualified technician. Removal of covers other than the front to replace lamp or
effect dish, or the fuseholder is considered a breach of warranty and will not be covered under any such agreement unless
authorized first by the company.

Troubleshooting

• If the unit is not functional – check main power supply is ‘on’ and check fuses.
• If the unit is not moving to the music check the sound-activation adjustment (when applicable)
• If after trying this solution you still have a problem contact your dealer or CHAUVET.

Contact Chauvet

USA
Tecnical Assistance: 1-800-762-1084  (954) 929-1115
E-Mail [email protected]

Caution

Do not obstruct the air vents.
Do not touch unit  while hot.
No user serviceable parts inside, please refer to CHAUVET for service.

Unit should be mounted in such a manner that the emitted beam will not strike people.

Power Connections

The unit is supplied with a power plug appropriate to its voltage and destination. Should any other 
connections be required they must be carried out with the following configuration.

Earth = Green/Yellow cable
Neutral = Blue cable
Live = Brown cable

In the USA & Europe, it is required that all plugs are 3-pin type i.e. with Earth/Ground connection.
In the UK, it is required that all mains plugs are fitted with 5A fuses.

Technical Specifications

Power

120V, 60Hz AC

240V, 50Hz Ac

Fuse

20mm Glass 2A Fast Blow

20mm Glass 1A Fast Blow

1 x 4.9mW Green Laser

1 x 4.9mW Green Laser

Diode

Part No. 4.9mW Green

Part No. 4.9mW Green

Dimensions

304 x 304 x 304mm / 12 x 12 x 12in

304 x 304 x 304mm / 12 x 12 x 12in

Weight

5 kg / 12.75 lbs

5 kg / 12.75 lbs

Summary of Contents for LGG-3000X

Page 1: ...dquarters 3000 North 29th Ct Hollywood Florida USA FL 33020 Tel 1 954 929 1115 Fax 1 954 929 5560 www ChauvetLighting com Photon Generator DMX LGG 3000X User Guide Please read these instructions carefully before use ...

Page 2: ...entilated areas taking care not to obstruct the air vents After use allow time to cool for safety and to ensure longevity before moving or touching The Photon Generator DMX LGG3000X is a DMX fixture that can be operated with Chauvet s DMX 6 controller DMX 40 DMX controller ShowXpress or any other universal DMX controller The LGG3000X will also work in stand alone mode either automatic or sound act...

Page 3: ... 4 5 6 7 8 9 10 Off On Value 1 2 4 8 16 32 64 128 256 Channel 1 Laser Channel 2 Pattern Control Mirror Rotation 255 Auto All Patterns 255 Sound Activated 250 Pattern 16 236 Pattern 15 245 Right Fast 222 Pattern 14 208 Pattern 13 205 Right Medium 194 Pattern 12 180 Pattern 11 168 Pattern 10 165 Right Slow 152 Pattern 9 138 Pattern 8 124 Pattern 7 125 Left Fast 110 Pattern 6 96 Pattern 5 84 Pattern ...

Page 4: ...upply before attempting to replace either lamps or fuse In order to replace the fuse disconnect from the main power supply first and then unscrew the fuseholder cover to reveal the fuse The unit has a label attached which indicates the correct fuse rating and you will also find this listed as part of the specifications for the unit later in this guide It is most important that replacement fuses ar...

Page 5: ... you still have a problem contact your dealer or CHAUVET Contact Chauvet USA Tecnical Assistance 1 800 762 1084 954 929 1115 E Mail tech chauvetlighting com Caution Do not obstruct the air vents Do not touch unit while hot No user serviceable parts inside please refer to CHAUVET for service Unit should be mounted in such a manner that the emitted beam will not strike people Power Connections The u...

Page 6: ... no fd e v i a t i o n p u r s u a n tt oL a s e rN o t i c eN o 5 0 d a t e dJ u l y2 6 2 0 0 1 Caution use of controls or adjustments or performance of procedures other than as specified herein may result in hazardous radiation exposure Warning Do not look directly into the Laser Prolonged exposure to single static laser beam can cause retinal damage CAUTION CLASS 3R LASER RADIATION WHEN OPEN AV...

Reviews: