background image

LASER RADIATION

AVOID DIRECT EYE EXPOSERE

CLASS 3R LASER PRODUCT

5.0 mW max CW Diode 532 nm

IEC/EN 60825-1, ed 1.2

Chauvet Lighting

3000 North 29th Ct.

Hollywood, Fl 33020 USA

Manufactured: January,2002

Complies with FDA performance

standards for laser products

with the exception of deviation

pursuant to Laser Notice No.

50, dated July 26, 2001

Caution- use of controls or adjustments or 

performance of procedures 

other than as specified herein may result in 

hazardous radiation exposure.

Warning: Do not look directly into the Laser!

(Prolonged exposure to single static laser beam can cause retinal damage)

CAUTION - CLASS 3R

LASER RADIATION WHEN

OPEN AVOID DIRECT EYE

E X P O S U R E

CAUTION - CLASS 3R

LASER RADIATION WHEN

OPEN AVOID DIRECT EYE

E X P O S U R E

Push button ON/OFF switch

Dip Switches must be
set or unit will not work.

Summary of Contents for LGG-3000X

Page 1: ...dquarters 3000 North 29th Ct Hollywood Florida USA FL 33020 Tel 1 954 929 1115 Fax 1 954 929 5560 www ChauvetLighting com Photon Generator DMX LGG 3000X User Guide Please read these instructions carefully before use ...

Page 2: ...entilated areas taking care not to obstruct the air vents After use allow time to cool for safety and to ensure longevity before moving or touching The Photon Generator DMX LGG3000X is a DMX fixture that can be operated with Chauvet s DMX 6 controller DMX 40 DMX controller ShowXpress or any other universal DMX controller The LGG3000X will also work in stand alone mode either automatic or sound act...

Page 3: ... 4 5 6 7 8 9 10 Off On Value 1 2 4 8 16 32 64 128 256 Channel 1 Laser Channel 2 Pattern Control Mirror Rotation 255 Auto All Patterns 255 Sound Activated 250 Pattern 16 236 Pattern 15 245 Right Fast 222 Pattern 14 208 Pattern 13 205 Right Medium 194 Pattern 12 180 Pattern 11 168 Pattern 10 165 Right Slow 152 Pattern 9 138 Pattern 8 124 Pattern 7 125 Left Fast 110 Pattern 6 96 Pattern 5 84 Pattern ...

Page 4: ...upply before attempting to replace either lamps or fuse In order to replace the fuse disconnect from the main power supply first and then unscrew the fuseholder cover to reveal the fuse The unit has a label attached which indicates the correct fuse rating and you will also find this listed as part of the specifications for the unit later in this guide It is most important that replacement fuses ar...

Page 5: ... you still have a problem contact your dealer or CHAUVET Contact Chauvet USA Tecnical Assistance 1 800 762 1084 954 929 1115 E Mail tech chauvetlighting com Caution Do not obstruct the air vents Do not touch unit while hot No user serviceable parts inside please refer to CHAUVET for service Unit should be mounted in such a manner that the emitted beam will not strike people Power Connections The u...

Page 6: ... no fd e v i a t i o n p u r s u a n tt oL a s e rN o t i c eN o 5 0 d a t e dJ u l y2 6 2 0 0 1 Caution use of controls or adjustments or performance of procedures other than as specified herein may result in hazardous radiation exposure Warning Do not look directly into the Laser Prolonged exposure to single static laser beam can cause retinal damage CAUTION CLASS 3R LASER RADIATION WHEN OPEN AV...