background image

 
 
 
 

Page 12 of 16 

Hurricane Haze 1D User Manual Rev. 1 

5.

 

Technical Information

 

 

 

Hazer Maintenance 

 

 

 

Do not allow the hazer  to become clogged. After every 40 hours of continuous 
operation, use CHAUVET  Fog Cleaner Quart (FCQ) through the system to prevent 
the accumulation of particulate matter in the heating element. 

The recommended cleaning procedure is as follows. 

1.  Unplug the product from power. 
2.  Empty all fog fluid from the machine. 
3.  Add cleaning solution to the tank. 
4.  Connect the product to power and allow it to warm up. 
5.  Run the unit in a well-ventilated area until the tank is almost empty. 

Do not 

allow the pump to run dry.

 

6.  Refill with hazer fluid to continue using the hazer. Run the machine briefly to 

clear any remaining cleaning solution from the pump and heater. 

 

Do not operate the machine without fluid at any time.

 

 

Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your 
Hurricane Haze 1D. Make sure you use FCQ regularly, no longer than 90 days 
between cleanings, to increase the life of your product. 

 

 

Storage

 

Before storing the hazer, run FCQ through the system as described in the cleaning 
procedure above; however, only follow steps 1 through 5

. Do not refill the tank with 

fog fluid if storing the hazer. 

Cleaning the system prior to storage will help prevent 

any particles from condensing inside the pump or heater while not in use.

 

 

Test-run your Hurricane Haze 1D  on a monthly basis to achieve the best 
performance. 

 
 

 

Summary of Contents for Hurricane Haze 1D

Page 1: ...User Manual ...

Page 2: ...imensions 6 3 Setup 7 AC Power 7 Fuse Replacement 7 Mounting 8 Orientation 8 Rigging 8 4 Operation 9 Control Panel Operation 9 Fluid Tank Indicator LEDs 9 Wired Timer Remote Operation 10 Menu Map 11 Configuration DMX 11 Starting Address 11 Configuration Standalone Mode 11 Manual Mode 11 DMX Channel Assignments and Values 11 1 CH 11 5 Technical Information 12 Hazer Maintenance 12 Storage 12 General...

Page 3: ...Text Conventions Convention Meaning Menu A key to be pressed on the product s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status Menu Settings A sequence of menu options to be followed ON A value to be entered or selected Icons Icon Meaning Critical installation ...

Page 4: ...receive this document This product is for indoor use only To prevent risk of fire or shock do not expose this product to rain or moisture Make sure there are no flammable materials close to the unit while operating Always install this product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots on the unit s housing are blocked Make ...

Page 5: ...D User Manual Rev 1 Page 5 of 16 2 Introduction Product Overview LED Display DMX In Out Remote Control Receiver Port Power In Fuse Holder On Off Switch Wireless Remote Manual Fog Button Fluid Level Indicator Fluid Tank ...

Page 6: ...Page 6 of 16 Hurricane Haze 1D User Manual Rev 1 Product Dimensions 12 80 in 325 mm 12 52 in 318 mm 9 84 in 250 mm 5 95 in 151 mm 7 95 in 202 mm 10 55 in 268 mm ...

Page 7: ...riate electrical ground to avoid the risk of electrocution or fire Never connect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement Disconnect this product from the power outlet before replacing the fuse 1 Wedge the tip of a flat head screwdriver into the slot of the fuse holder 2 Pry the fuse out ...

Page 8: ...mounting clamp of appropriate weight capacity The bracket has a 13 mm hole which is appropriate for this purpose When mounting this product overhead always use a safety cable Before deciding on a location for this product always make sure that it will be easy to access the unit for maintenance and programming purposes When power linking multiple products you must always consider the length of the ...

Page 9: ... for the three types of methods used to control the operation of your Hurricane Haze 1D A DMX controller will take priority control over the digital display and Remote Control The priority control levels are 1 DMX 2 Remote controller 3 Digital display Fluid Tank Indicator LEDs Indicator LEDs show the status of the fill tank as follows Red the heater is currently warming up Blue the hazer is ready ...

Page 10: ...s pressed again 4 Set the INTERVAL DURATION and OUTPUT adjustment knobs to the desired positions INTERVAL knob sets the amount of time in between bursts of fog DURATION knob sets the length of time that the fog machine will run during the burst OUTPUT knob adjusts the fog output 5 Press the CONTINUOUS latching button and the fog machine outputs fog until the button is pressed again The Manual Powe...

Page 11: ... could restrict the access to some of the product s channels If you are not familiar with the DMX protocol download the DMX Primer from www chauvetlighting com To select the starting address do the following 1 Press MENU repeatedly until d shows on the display 2 Use UP or DOWN to select the starting address Configuration Standalone Mode Set this product in one of the standalone modes to control it...

Page 12: ... dry 6 Refill with hazer fluid to continue using the hazer Run the machine briefly to clear any remaining cleaning solution from the pump and heater Do not operate the machine without fluid at any time Fog Cleaner Quart FCQ was specifically developed by Chauvet to clean your Hurricane Haze 1D Make sure you use FCQ regularly no longer than 90 days between cleanings to increase the life of your prod...

Page 13: ... Excessive load on the circuit Make sure that the total load does not exceed 80 of the breaker or fuse nominal current Short circuit along the power lines Check the power lines and power cords Product does not power up No energy on power outlet Check power outlet Change to another outlet Loose or damaged power cord Check the power cord Blown fuse Replace blown fuse with a good one of the same type...

Page 14: ... number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return You must send the merchandise prepaid in its original box and with its original packing and accessories Chauvet will not issue call tags Clearly label the package with the RMA number Chauvet will refuse any product returned without an RMA number Write the RM...

Page 15: ...ing eu World Wide Web www chauvetlighting eu General Information Chauvet Europe Ltd Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Email uktech chauvetlighting com World Wide Web www chauvetlighting co uk MEXICO General Information Chauvet Mexico Address Av Santa Ana 30 Parque Industrial Lerma Lerma Mexi...

Page 16: ... 120 V 60 Hz 230 V 50 Hz Consumption 840 W 6 8 A 840 W 3 7 A Fuse size F 10 A 250 V F 10 A 250 V Power I O Input Connectors IEC Cord plug Edison Operation Heat up Time Tank Capacity Fluid Consumption 1 min 1 5 l 10 ml min Fog output CFM 700 Approved Fluids Chauvet Haze Fluid Gallon HFG Thermal Maximum External Temp Cooling System 104 F 40 C Convection DMX I O Connectors Connector Type Channel Rang...

Reviews: