background image

22

Warranty

Product Manual - VaporMan 125

®

 Manifold Vaporizer System

of Sale and this Warranty Policy, this Warranty Policy shall 

control 

Warranty Claims Procedure

1   All warranty claims must be previously authorized 

by Chart Inc  Telephone / electronic approval may 

be obtained by contacting Chart’s Beverage Systems 

Technical / Customer Services at:

1-800-247-4446

1-800-253-1769

Fax: 1-952-758-8275

Or by writing to:

Chart Inc 

407 7th Street NW

New Prague, MN 56071

2   Authorization must be obtained from Chart prior to 

shipping any Equipment to Chart facilities  In order to 

process the return of a tank its model and serial number 

must be provided  If approved, a Return Material 

Authorization (RMA) number will be provided  The 

RMA number must be prominently indicated on the 

packing slip and any packaging that accompanies the 

goods being returned  The customer returning the goods 

is responsible for all freight, proper packing, and any 

damage incurred during shipment of the goods back to 

Chart 

Summary of Contents for VaporMan 125

Page 1: ...Part Number 20749848 Rev B 2018 Chart Inc Designed and Built by Chart Inc 407 7th Street NW New Prague MN 56071 USA 800 400 4683 Product Manual VaporMan 125 Manifold Vaporizer System...

Page 2: ......

Page 3: ...ow Regulator 6 Operations 7 Initial Inspections 7 Filling Procedures 7 Installing the VaporMan 125 Unit 7 Plumbing Procedures 8 Carbo Max 1000 Bulk CO2 System Parts to be Added 8 Carbo Max 1000 Bulk C...

Page 4: ...aporMan 125 Unit with Carbo Max 750 Bulk CO2 System 19 VaporMan 125 Unit with Carbo Max 1000 Bulk CO2 System 19 VaporMan 125 Unit with Perma Cyl MicroBulk Storage System 20 Warranty 21 Warranty Policy...

Page 5: ...ls and kits provided by Chart This manual contains information regarding the safe operation and handling of liquid carbon dioxide with the cylinder and the vaporizer manifold system It should be thoro...

Page 6: ...f a condition that can result in equipment or component damage Note A statement that contains information that is important enough to emphasize or repeat Acronyms Abbreviations The following acronyms...

Page 7: ...ith liquid CO2 cold pipes and equipment or cold gas exists Safety goggles or a face shield should be worn at all times when connecting to fill connections while filling the tank and during disconnecti...

Page 8: ...Monitoring Systems The Analox 50 and Ax 50 Carbon Dioxide Analyzers are precision instruments that provide continuous accurate monitoring of CO2 levels to ensure a safe working environment for your em...

Page 9: ...a plug and play assembly The vaporizers are connected in a specific order and the vaporizer selection was intentional The parallel vaporizer is used to vaporize the liquid into cold gas The gas is th...

Page 10: ...bo Max 1000 Bulk CO2 System tanks or who have one Perma Cyl MicroBulk Storage System tank there are two optional kits that will need to be purchased as well The kit names are KIT CARBOMAX VAPORMAN 100...

Page 11: ...ns A place that has circulation is recommended to aid in melting the ice that might build up on the vaporizers during operation The VaporMan 125 unit will then need to be connected to the tank or tank...

Page 12: ...in the following illustrations you will remove the Economizing sections Gas Use sections and the Pressure Building sections The parts to be reused are shown on top as well as the parts to be added Car...

Page 13: ...9 Operations Product Manual VaporMan 125 Manifold Vaporizer System Carbo Max 750 Bulk CO2 System Parts to be Added Carbo Max 750 Bulk CO2 System Parts to be Removed...

Page 14: ...not connected the tanks may not distribute CO2 to the VaporMan 125 unit equally The check valves are in place to prevent any back flow into each tank The check valves also ensure that the tanks equal...

Page 15: ...dy VaporMan 125 system pressure is too low or does not build pressure at a sufficient rate VaporMan 125 unit or system is leaking If the pressure does not build and stays at a setting lower than desir...

Page 16: ......

Page 17: ...re Designation Description Function PG 1 PG 2 DIAL 0 400 PSI 1 4 MPT CBM PN 13321014 PRESSURE GAUGE TANK PRESSURE ECON PRESSURE R 1 REGULATOR 250 NPT 150 PSI ECON PN 13154842 ECONOMIZER REGULATOR RV 2...

Page 18: ...13154842 ECONOMIZER REGULATOR R 2 REGULATOR 250 NPT 200 PSI SF PN 13154834 SURE FILL REGULATOR RV 1 RV BRS 1 2MPT 300 PSI PN 11708400 PRIMARY SAFETY RELIEF VALVE RV 2 RV BRS 1 2MPT 450 PSI PN 1170845...

Page 19: ...4 MPT CBM PN 11940305 R 1 REGULATOR 250 NPT 150 PSI ECON PN 13154842 R 2 REGULATOR 250 NPT 200 PSI SF PN 13154834 R 3 REGULATOR 250 NPT 125 PSI PB PN 14743180 RV 1 RV BRS 1 2MPT 300 PSI PN 11708400 R...

Page 20: ...16 Specifications Product Manual VaporMan 125 Manifold Vaporizer System VaporMan 125 Unit with Perma Cyl MicroBulk Storage System...

Page 21: ...DICATOR PI 1 PRESSURE INDICATOR R 1 PRESS BUILDING REG R 2 SUREFILL REG RV 1 RELIEF VALVE RV 2 LINE RELIEV BD 1 BURST DISC Piping Ref No Description A TOP FILL B LIQUID WITHDRAWAL C PRESSURE BUILDING...

Page 22: ...18 Specifications Product Manual VaporMan 125 Manifold Vaporizer System Set up and Dimensions VaporMan 125 Unit...

Page 23: ...19 Specifications Product Manual VaporMan 125 Manifold Vaporizer System VaporMan 125 Unit with Carbo Max 750 Bulk CO2 System VaporMan 125 Unit with Carbo Max 1000 Bulk CO2 System...

Page 24: ...20 Specifications Product Manual VaporMan 125 Manifold Vaporizer System VaporMan 125 Unit with Perma Cyl MicroBulk Storage System...

Page 25: ...fications in any way to the Equipment without Chart s prior written approval shall render this warranty void This limited warranty does not apply to Equipment comprised of materials provided or a desi...

Page 26: ...Or by writing to Chart Inc 407 7th Street NW New Prague MN 56071 2 Authorization must be obtained from Chart prior to shipping any Equipment to Chart facilities In order to process the return of a tan...

Reviews: